Researcher profile

H. Simgen

H. Simgen contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
13works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2026arXiv

Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT

We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}ν\text{NS}$) becomes an irreducible background.

preprint2022arXiv

Application and modeling of an online distillation method to reduce krypton and argon in XENON1T

A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of $(360 \pm 60)$ ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors.

preprint2022arXiv

Double-Weak Decays of $^{124}$Xe and $^{136}$Xe in the XENON1T and XENONnT Experiments

We present results on the search for double-electron capture ($2ν\text{ECEC}$) of $^{124}$Xe and neutrinoless double-$β$ decay ($0νββ$) of $^{136}$Xe in XENON1T. We consider captures from the K- up to the N-shell in the $2ν\text{ECEC}$ signal model and measure a total half-life of $T_{1/2}^{2ν\text{ECEC}}=(1.1\pm0.2_\text{stat}\pm0.1_\text{sys})\times 10^{22}\;\text{yr}$ with a $0.87\;\text{kg}\times\text{yr}$ isotope exposure. The statistical significance of the signal is $7.0\,σ$. We use XENON1T data with $36.16\;\text{kg}\times\text{yr}$ of $^{136}$Xe exposure to search for $0νββ$. We find no evidence of a signal and set a lower limit on the half-life of $T_{1/2}^{0νββ} > 1.2 \times 10^{24}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$. This is the best result from a dark matter detector without an enriched target to date. We also report projections on the sensitivity of XENONnT to $0νββ$. Assuming a $275\;\text{kg}\times\text{yr}$ $^{136}$Xe exposure, the expected sensitivity is $T_{1/2}^{0νββ} > 2.1 \times 10^{25}\;\text{yr}\; \text{at}\; 90\,\%\;\text{CL}$, corresponding to an effective Majorana mass range of $\langle m_{ββ} \rangle < (0.19 - 0.59)\;\text{eV/c}^2$.

preprint2022arXiv

GPU-based optical simulation of the DARWIN detector

Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

preprint2022arXiv

Pulse shape analysis in GERDA Phase II

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge using isotopically enriched high purity germanium detectors at the Laboratori Nazionali del Gran Sasso of INFN. After Phase I (2011-2013), the experiment benefited from several upgrades, including an additional active veto based on LAr instrumentation and a significant increase of mass by point-contact germanium detectors that improved the half-life sensitivity of Phase II (2015-2019) by an order of magnitude. At the core of the background mitigation strategy, the analysis of the time profile of individual pulses provides a powerful topological discrimination of signal-like and background-like events. Data from regular $^{228}$Th calibrations and physics data were both considered in the evaluation of the pulse shape discrimination performance. In this work, we describe the various methods applied to the data collected in GERDA Phase II corresponding to an exposure of 103.7 kg$\cdot$yr. These methods suppress the background by a factor of about 5 in the region of interest around Q$_{ββ}$ = 2039 keV, while preserving (81$\pm$3)% of the signal. In addition, an exhaustive list of parameters is provided which were used in the final data analysis.

preprint2021arXiv

Calibration of the GERDA experiment

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge with an array of about 40 high-purity isotopically-enriched germanium detectors. The experimental signature of the decay is a monoenergetic signal at Q$_{ββ}$ = 2039.061(7)keV in the measured summed energy spectrum of the two emitted electrons. Both the energy reconstruction and resolution of the germanium detectors are crucial to separate a potential signal from various backgrounds, such as neutrino-accompanied double-$β$ decays allowed by the Standard Model. The energy resolution and stability were determined and monitored as a function of time using data from regular $^{228}$Th calibrations. In this work, we describe the calibration process and associated data analysis of the full GERDA dataset, tailored to preserve the excellent resolution of the individual germanium detectors when combining data over several years.

preprint2020arXiv

$^{222}$Rn emanation measurements for the XENON1T experiment

The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $^{222}$Rn emanation measurements performed for the XENON1T dark matter experiment. Together with the bulk impurity screening campaign, the results enabled us to select the radio-purest construction materials, targeting a $^{222}$Rn activity concentration of 10 $μ$Bq/kg in 3.2 t of xenon. The knowledge of the distribution of the $^{222}$Rn sources allowed us to selectively eliminate critical components in the course of the experiment. The predictions from the emanation measurements were compared to data of the $^{222}$Rn activity concentration in XENON1T. The final $^{222}$Rn activity concentration of (4.5 $\pm$ 0.1) $μ$Bq/kg in the target of XENON1T is the lowest ever achieved in a xenon dark matter experiment.

preprint2020arXiv

Energy resolution and linearity of XENON1T in the MeV energy range

Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 $σ/μ$ is as low as (0.80$\pm$0.02) % in its one-ton fiducial mass, and for single-site interactions at $Q_{ββ}$. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.

preprint2020arXiv

Final Results of GERDA on the Search for Neutrinoless Double-$β$ Decay

The GERmanium Detector Array (GERDA) experiment searched for the lepton-number-violating neutrinoless double-$β$ ($0νββ$) decay of $^{76}$Ge, whose discovery would have far-reaching implications in cosmology and particle physics. By operating bare germanium diodes, enriched in $^{76}$Ge, in an active liquid argon shield, GERDA achieved an unprecedently low background index of $5.2\times10^{-4}$ counts/(keV$\cdot$kg$\cdot$yr) in the signal region and met the design goal to collect an exposure of 100 kg$\cdot$yr in a background-free regime. When combined with the result of Phase I, no signal is observed after 127.2 kg$\cdot$yr of total exposure. A limit on the half-life of $0νββ$ decay in $^{76}$Ge is set at $T_{1/2}>1.8\times10^{26}$ yr at 90% C.L., which coincides with the sensitivity assuming no signal.

preprint2020arXiv

Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T

Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, which leads to the excitation and ionization of the recoiling atom (the Migdal effect) or the emission of a Bremsstrahlung photon. In this letter, we report on a probe of low-mass dark matter with masses down to about 85 MeV/c$^2$ by looking for electronic recoils induced by the Migdal effect and Bremsstrahlung, using data from the XENON1T experiment. Besides the approach of detecting both scintillation and ionization signals, we exploit an approach that uses ionization signals only, which allows for a lower detection threshold. This analysis significantly enhances the sensitivity of XENON1T to light dark matter previously beyond its reach.

preprint2020arXiv

Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe

The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, using a fiducial volume of 5t of natural xenon and 10$\,$yr of operation with a background rate of less than 0.2$~$events/(t$\cdot$yr) in the energy region of interest. This sensitivity is based on a detailed Monte Carlo simulation study of the background and event topologies in the large, homogeneous target. DARWIN will be comparable in its science reach to dedicated double beta decay experiments using xenon enriched in $^{136}$Xe.

preprint2020arXiv

The first search for bosonic super-WIMPs with masses up to 1 MeV/c$^2$ with GERDA

We present the first search for bosonic super-WIMPs as keV-scale dark matter candidates performed with the GERDA experiment. GERDA is a neutrinoless double-beta decay experiment which operates high-purity germanium detectors enriched in $^{76}$Ge in an ultra-low background environment at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN in Italy. Searches were performed for pseudoscalar and vector particles in the mass region from 60 keV/c$^2$ to 1 MeV/c$^2$. No evidence for a dark matter signal was observed, and the most stringent constraints on the couplings of super-WIMPs with masses above 120 keV/c$^2$ have been set. As an example, at a mass of 150 keV/c$^2$ the most stringent direct limits on the dimensionless couplings of axion-like particles and dark photons to electrons of $g_{ae} < 3 \cdot 10^{-12}$ and ${α&#39;}/α < 6.5 \cdot 10^{-24}$ at 90% credible interval, respectively, were obtained.

preprint2017arXiv

Searching for neutrinoless double beta decay with GERDA

The GERmanium Detector Array (GERDA) experiment located at the INFN Gran Sasso Laboratory (Italy), is looking for the neutrinoless double beta decay of Ge76, by using high-purity germanium detectors made from isotopically enriched material. The combination of the novel experimental design, the careful material selection for radio-purity and the active/passive shielding techniques result in a very low residual background at the Q-value of the decay, about 1e-3 counts/(keV kg yr). This makes GERDA the first experiment in the field to be background-free for the complete design exposure of 100 kg yr. A search for neutrinoless double beta decay was performed with a total exposure of 47.7 kg yr: 23.2 kg yr come from the second phase (Phase II) of the experiment, in which the background is reduced by about a factor of ten with respect to the previous phase. The analysis presented in this paper includes 12.4 kg yr of new Phase II data. No evidence for a possible signal is found: the lower limit for the half-life of Ge76 is 8.0e25 yr at 90% CL. The experimental median sensitivity is 5.8e25 yr. The experiment is currently taking data. As it is running in a background-free regime, its sensitivity grows linearly with exposure and it is expected to surpass 1e26 yr within 2018.