Source author record

Gopalakrishnan Balasubramanian

Gopalakrishnan Balasubramanian appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2019arXiv

Tapered ultra-high Numerical Aperture optical fiber tip for Nitrogen Vacancy ensembles based endoscope in a fluidic environment

Fixing a diamond containing a high density of Nitrogen-Vacancy (NV) center ensembles on the apex of a multimode optical fiber (MMF) extends the applications of NV-based endoscope sensors. Replacing the normal MMF with a tapered MMF (MMF-taper) has enhanced the fluorescence (FL) collection efficiency from the diamond and achieved a high spatial resolution NV-based endoscope. The MMF-taper's high FL collection efficiency is the direct result of multiple internal reflections in the tapered region caused by silica, which has a higher refractive index (RI) than the surrounding air. However, for applications involving fluidic environments whose RI is close to or higher than that of the silica, the MMF-taper loses its FL collection significantly. Here, to overcome this challenge, we replaced the MMF-taper with an ultra-high numerical aperture (NA) microstructured optical fiber (MOF) which is tapered and sealed its air capillaries at the tapered end. Since the end-sealed air capillaries along the tapered MOF (MOF-taper) have isolated the MOF core from the surrounding medium, the core retains its high FL collection and NV excitation efficiency in liquids regardless of their RI values. Such a versatile NV-based endoscope could potentially find broad applications in fluidic environments where many biological processes and chemical reactions occur.

preprint2015arXiv

A nitrogen-vacancy spin based molecular structure microscope using multiplexed projection reconstruction

Methods and techniques to measure and image beyond the state-of-the-art have always been influential in propelling basic science and technology. Because current technologies are venturing into nanoscopic and molecular-scale fabrication, atomic-scale measurement techniques are inevitable. One such emerging sensing method uses the spins associated with nitrogen-vacancy (NV) defects in diamond. The uniqueness of this NV sensor is its atomic size and ability to perform precision sensing under ambient conditions conveniently using light and microwaves (MW). These advantages have unique applications in nanoscale sensing and imaging of magnetic fields from nuclear spins in single biomolecules. During the last few years, several encouraging results have emerged towards the realization of an NV spin-based molecular structure microscope. Here, we present a projection-reconstruction method that retrieves the three-dimensional structure of a single molecule from the nuclear spin noise signatures. We validate this method using numerical simulations and reconstruct the structure of a molecular phantom \b{eta}-cyclodextrin, revealing the characteristic toroidal shape.

preprint2015arXiv

Dynamical sensitivity control of a single-spin quantum sensor

The Nitrogen-Vacancy (NV) defect in diamond is a unique quantum system that offers precision sensing of nanoscale physical quantities beyond the current state-of-the-art. Here we present a method to controllably encode the interactions in the population of the spin states, thereby introducing a way to control the sensitivity of a single spin as a continuum in contrast to free-evolution based methods. By adopting this feature we demonstrate high-accuracy NV magnetometry without 2pi ambiguities, enhance the dynamic range by a factor of 4*10^3 achieve interaction times exceeding 2 ms in off-the-shelf diamond. We perform nuclear spin-noise spectroscopy in the frequency domain by dynamically controlling the NV spin's sensitivity piecewise and in a smooth manner thereby precluding harmonic artefacts and undesired interactions. On a broader perspective dynamical sensitivity control provides an elegant handle on the inherent dynamics of quantum systems, while offering decisive advantages for NV centre applications notably in quantum controls and single molecule NMR/MRI.

preprint2011arXiv

Sensing electric fields using single diamond spins

The ability to sensitively detect charges under ambient conditions would be a fascinating new tool benefitting a wide range of researchers across disciplines. However, most current techniques are limited to low-temperature methods like single-electron transistors (SET), single-electron electrostatic force microscopy and scanning tunnelling microscopy. Here we open up a new quantum metrology technique demonstrating precision electric field measurement using a single nitrogen-vacancy defect centre(NV) spin in diamond. An AC electric field sensitivity reaching ~ 140V/cm/\surd Hz has been achieved. This corresponds to the electric field produced by a single elementary charge located at a distance of ~ 150 nm from our spin sensor with averaging for one second. By careful analysis of the electronic structure of the defect centre, we show how an applied magnetic field influences the electric field sensing properties. By this we demonstrate that diamond defect centre spins can be switched between electric and magnetic field sensing modes and identify suitable parameter ranges for both detector schemes. By combining magnetic and electric field sensitivity, nanoscale detection and ambient operation our study opens up new frontiers in imaging and sensing applications ranging from material science to bioimaging.

preprint2010arXiv

High sensitivity magnetic imaging using an array of spins in diamond

We present a solid state magnetic field imaging technique using a two dimensional array of spins in diamond. The magnetic sensing spin array is made of nitrogen-vacancy (NV) centers created at shallow depths. Their optical response is used for measuring external magnetic fields in close proximity. Optically detected magnetic resonance (ODMR) is readout from a 60x60 $μ$m field of view in a multiplexed manner using a CCD camera. We experimentally demonstrate full two-dimensional vector imaging of the magnetic field produced by a pair of current carrying micro-wires. The presented widefield NV magnetometer offers in addition to its high magnetic sensitivity of 20 nT/$\sqrt{Hz}$ and vector reconstruction, an unprecedented spatio-temporal resolution and functionality at room temperature.

preprint2010arXiv

Sub-optical resolution of single spins using magnetic resonance imaging at room temperature in diamond

There has been much recent interest in extending the technique of magnetic resonance imaging (MRI) down to the level of single spins with sub-optical wavelength resolution. However, the signal to noise ratio for images of individual spins is usually low and this necessitates long acquisition times and low temperatures to achieve high resolution. An exception to this is the nitrogen-vacancy (NV) color center in diamond whose spin state can be detected optically at room temperature. Here we apply MRI to magnetically equivalent NV spins in order to resolve them with resolution well below the optical wavelength of the readout light. In addition, using a microwave version of MRI we achieved a resolution that is 1/270 size of the coplanar striplines, which define the effective wavelength of the microwaves that were used to excite the transition. This technique can eventually be extended to imaging of large numbers of NVs in a confocal spot and possibly to image nearby dark spins via their mutual magnetic interaction with the NV spin.