Source author record

Gokhan Kurt

Gokhan Kurt appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Analysis Of Radiation Dose Distribution Inhomogenity Effects In Gamma Knife Radiosurgery Using Geant4

The Monte Carlo method is widely used in the Gamma Knife dose distribution calculations. In this study, Monte-Carlo simulation with Geant4 was applied to determine Leksell Gamma Knife dose distribution for homogeneous solid water and heterogeneous brain phantoms, and primarily focused on the differences arising from the effects of inhomogeneity. The relative dose graphs were displayed for different collimator diameters. The dose values from the maximal interval regions were determined and compared. It seen that when the collimator size was 4mm, the mean maximum relative dose point was at 47mm for water phantom and at 44mm for the brain. The difference found was about 6.38%. The differences among the results determined for water and brain were ranged from 2 to 17%. As a result, the inhomogeneity effect should be considered in dose calculation in Gamma Knife planning system. Keywords: Radiosurgery, Gamma Knife, γ-Rays, Inhomogeneity, Brain

preprint2021arXiv

Geant4 based Dosimetry Evaluation for Gamma Knife using Different Phantom Materials

This study analyses the dose difference for a variety of phantom materials that can be used for Leksell Gamma Knife. These materials have properties that are very similar to the human tissue not including the skull bone. Geant4 was employed in the analysis the dose distributions for collimator helmet sizes of 4mm and 8mm. The phantom had a radius of 80mm. Water, brain, PMMA (Poly-methyl methacrylate) and polystyrene were used as the material types. Results showed no considerable differences for radiation dosimetries depending on the material types. In addition, the polystyrene and PMMA (Poly-methyl methacrylate) phantom are also suitable for measuring the dose profiles of the Gamma Knife unit.