Source author record

Giuseppe D' Alessandro

Giuseppe D' Alessandro appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Efficient Differential Fourier-Transform Spectrometer for precision Sunyaev-Zel'dovich effect measurements

Precision measurements of the Sunyaev-Zel'dovich effect in clusters of galaxies require excellent rejection of common-mode signals and wide frequency coverage. We describe an imaging, efficient, differential Fourier transform spectrometer (FTS), optimized for measurements of faint brightness gradients at millimeter wavelengths. Our instrument is based on a Martin-Puplett interferometer (MPI) configuration. We combined two MPIs working synchronously to use the whole input power. In our implementation the observed sky field is divided into two halves along the meridian, and each half-field corresponds to one of the two input ports of the MPI. In this way, each detector in the FTS focal planes measures the difference in brightness between two sky pixels, symmetrically located with respect to the meridian. Exploiting the high common-mode rejection of the MPI, we can measure low sky brightness gradients over a high isotropic background. The instrument works in the range $\sim$ 1$-$20 cm$^{-1}$ (30$-$600 GHz), has a maximum spectral resolution $1/(2 \ OPD) = 0.063 \ cm^{-1}$ (1.9 GHz), and an unvignetted throughput of 2.3 cm$^2$sr. It occupies a volume of 0.7$\times$0.7$\times$0.33 m$^3$ and has a weight of 70 kg. This design can be implemented as a cryogenic unit to be used in space, as well as a room-temperature unit working at the focus of suborbital and ground-based mm-wave telescopes. The first in-flight test of the instrument is with the OLIMPO experiment on a stratospheric balloon; a larger implementation is being prepared for the Sardinia radio telescope.

preprint2012arXiv

On the emissivity of wire-grid polarizers for astronomical observations at mm-wavelengths

We have measured, using a custom setup, the emissivity of metallic wire-grids, suitable for polarimeters and interferometers at mm and far infrared wavelengths. We find that the effective emissivity of these devices is of the order of a few %, depending on fabrication technology and aging. We discuss their use in astronomical instruments, with special attention to Martin Puplett Interferometers in low-background applications, like astronomical observations of the Cosmic Microwave Background.

preprint2011arXiv

Low-resolution spectroscopy of the Sunyaev-Zel'dovich effect and estimates of cluster parameters

The Sunyaev-Zel'dovich (SZ) effect is a powerful tool for studying clusters of galaxies and cosmology. Large mm-wave telescopes are now routinely detecting and mapping the SZ effect in a number of clusters, measure their comptonisation parameter and use them as probes of the large-scale structure and evolution of the universe. We show that estimates of the physical parameters of clusters (optical depth, plasma temperature, peculiar velocity, non-thermal components etc.) obtained from ground-based multi-band SZ photometry can be significantly biased, owing to the reduced frequency coverage, to the degeneracy between the parameters and to the presence of a number of independent components larger than the number of frequencies measured. We demonstrate that low-resolution spectroscopic measurements of the SZ effect that also cover frequencies $> 270$ GHz are effective in removing the degeneracy. We used accurate simulations of observations with lines-of-sight through clusters of galaxies with different experimental configurations (4-band photometers, 6-band photometer, multi-range differential spectrometer, full coverage spectrometers) and different intracluster plasma stratifications. We find that measurements carried out with ground-based few-band photometers are biased towards high electron temperatures and low optical depths, and require coverage of high frequency and/or independent complementary observations to produce unbiased information; a differential spectrometer that covers 4 bands with a resolution of $\sim 6 \ GHz$ eliminates most if not all bias; full-range differential spectrometers are the ultimate resource that allows a full recovery of all parameters.