Researcher profile

Gilad Liberman

Gilad Liberman contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Optimized multi-axis spiral projection MR fingerprinting with subspace reconstruction for rapid whole-brain high-isotropic-resolution quantitative imaging

Purpose: To improve image quality and accelerate the acquisition of 3D MRF. Methods: Building on the multi-axis spiral-projection MRF technique, a subspace reconstruction with locally low rank (LLR) constraint and a modified spiral-projection spatiotemporal encoding scheme termed tiny-golden-angle-shuffling (TGAS) were implemented for rapid whole-brain high-resolution quantitative mapping. The LLR regularization parameter and the number of subspace bases were tuned using retrospective in-vivo data and simulated examinations, respectively. B0 inhomogeneity correction using multi-frequency interpolation was incorporated into the subspace reconstruction to further improve the image quality by mitigating blurring caused by off-resonance effect. Results: The proposed MRF acquisition and reconstruction framework can produce provide high quality 1-mm isotropic whole-brain quantitative maps in a total acquisition time of 1 minute 55 seconds, with higher-quality results than ones obtained from the previous approach in 6 minutes. The comparison of quantitative results indicates that neither the subspace reconstruction nor the TGAS trajectory induce bias for T1 and T2 mapping. High quality whole-brain MRF data were also obtained at 0.66-mm isotropic resolution in 4 minutes using the proposed technique, where the increased resolution was shown to improve visualization of subtle brain structures. Conclusion: The proposed TGAS-SPI-MRF with optimized spiral-projection trajectory and subspace reconstruction can enable high-resolution quantitative mapping with faster acquisition speed.

preprint2020arXiv

Improving MRI's slice selectivity in the presence of strong, metal-derived inhomogeneities

Purpose: To develop schemes that deliver faithful 2D slices near field heterogeneities of the kind arising from non-ferromagnetic metal implants, with reduced artifacts and shorter scan times. Methods: An excitation scheme relying on cross-term spatio-temporal encoding (xSPEN) was used as basis for developing the new inhomogeneity-insensitive, slice-selective pulse scheme. The resulting Fully refOCUSED cross-term SPatiotemporal ENcoding (FOCUSED-xSPEN) approach involved four adiabatic sweeps. The method was evaluated in silico, in vitro and in vivo using mice models, and compared against a number of existing and of novel alternatives based on both conventional and swept RF pulses, including an analogous method based on LASER's selectivity spatial selectivity. Results: Calculations and experiments confirmed that multi-sweep derivatives of xSPEN and LASER can deliver localized excitation profiles, centered at the intended positions and endowed with enhanced immunity to B0 and B1 distortions. This, however, is achieved at the expense of higher SAR than non-swept counterparts. Furthermore, single-shot FOCUSED-xSPEN and LASER profiles covered limited off-resonance ranges. This could be extended to bands covering arbitrary off-resonance values with uniform slice widths, by looping the experiments over a number of scans possessing suitable transmission and reception offsets. Conclusions: A series of novel approaches were introduced to select slices near metals, delivering robustness against Bo and B1+ field inhomogeneities.