Researcher profile

Gibion Makiwa

Gibion Makiwa contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2016arXiv

Far-infrared/sub-millimetre properties of pre-stellar cores L1521E, L1521F and L1689B as revealed by the Herschel SPIRE instrument -- I. Central positions

Dust grains play a key role in the physics of star-forming regions, even though they constitute only $\sim$1 % of the mass of the interstellar medium. The derivation of accurate dust parameters such as temperature ($T_{dust}$), emissivity spectral index ($β$) and column density requires broadband continuum observations at far-infrared wavelengths. We present Herschel-SPIRE Fourier Transform Spectrometer (FTS) measurements of three starless cores: L1521E, L1521F and L1689B, covering wavelengths between 194 and 671 $μ$m. This paper is the first to use our recently updated SPIRE-FTS intensity calibration, yielding a direct match with SPIRE photometer measurements of extended sources. In addition, we carefully assess the validity of calibration schemes depending on source extent and on the strength of background emission. The broadband far-infrared spectra for all three sources peak near 250 $μ$m. Our observations therefore provide much tighter constraints on the spectral energy distribution (SED) shape than measurements that do not probe the SED peak. The spectra are fitted using modified blackbody functions, allowing both $T_{dust}$ and $β$ to vary as free parameters. This yields $T_{dust}$ of 9.8$\pm$0.2 K, 15.6$\pm$0.5 K and 10.9$\pm$0.2 K and corresponding $β$ of 2.6$\mp$0.9, 0.8$\mp$0.1 and 2.4$\mp$0.8 for L1521E, L1521F and L1689B respectively. The derived core masses are 1.0$\pm$0.1, 0.10$\pm$0.01 and 0.49$\pm$0.05 $M_{\odot}$, respectively. The core mass/Jeans mass ratios for L1521E and L1689B exceed unity indicating that they are unstable to gravitational collapse, and thus pre-stellar cores. By comparison, the elevated temperature and gravitational stability of L1521F support previous arguments that this source is more evolved and likely a protostar.

preprint2014arXiv

Herschel SPIRE FTS Spectral Mapping Calibration

The Herschel SPIRE Fourier transform spectrometer (FTS) performs spectral imaging in the 447-1546 GHz band. It can observe in three spatial sampling modes: sparse mode, with a single pointing on sky, or intermediate or full modes with 1 and 1/2 beam spacing, respectively. In this paper, we investigate the uncertainty and repeatability for fully sampled FTS mapping observations. The repeatability is characterised using nine observations of the Orion Bar. Metrics are derived based on the ratio of the measured intensity in each observation compared to that in the combined spectral cube from all observations. The mean relative deviation is determined to be within 2%, and the pixel-by-pixel scatter is ~7%. The scatter increases towards the edges of the maps. The uncertainty in the frequency scale is also studied, and the spread in the line centre velocity across the maps is found to be ~15 km/s. Other causes of uncertainty are also discussed including the effect of pointing and the additive uncertainty in the continuum.

preprint2013arXiv

Astronomical imaging Fourier spectroscopy at far-infrared wavelengths

The principles and practice of astronomical imaging Fourier transform spectroscopy (FTS) at far-infrared wavelengths are described. The Mach-Zehnder interferometer design has been widely adopted for current and future imaging FTS instruments; we compare this design with two other common interferometer formats. Examples of three instruments based on the Mach-Zehnder design are presented. The techniques for retrieving astrophysical parameters from the measured spectra are discussed using calibration data obtained with the Herschel SPIRE instrument. The paper concludes with an example of imaging spectroscopy obtained with the SPIRE FTS instrument.

preprint2013arXiv

Observing Extended Sources with the \Herschel SPIRE Fourier Transform Spectrometer

The Spectral and Photometric Imaging Receiver (SPIRE) on the European Space Agency&#39;s Herschel Space Observatory utilizes a pioneering design for its imaging spectrometer in the form of a Fourier Transform Spectrometer (FTS). The standard FTS data reduction and calibration schemes are aimed at objects with either a spatial extent much larger than the beam size or a source that can be approximated as a point source within the beam. However, when sources are of intermediate spatial extent, neither of these calibrations schemes is appropriate and both the spatial response of the instrument and the source&#39;s light profile must be taken into account and the coupling between them explicitly derived. To that end, we derive the necessary corrections using an observed spectrum of a fully extended source with the beam profile and the source&#39;s light profile taken into account. We apply the derived correction to several observations of planets and compare the corrected spectra with their spectral models to study the beam coupling efficiency of the instrument in the case of partially extended sources. We find that we can apply these correction factors for sources with angular sizes up to θ_{D} ~ 17&#34;. We demonstrate how the angular size of an extended source can be estimated using the difference between the sub-spectra observed at the overlap bandwidth of the two frequency channels in the spectrometer, at 959<ν<989 GHz. Using this technique on an observation of Saturn, we estimate a size of 17.2&#34;, which is 3% larger than its true size on the day of observation. Finally, we show the results of the correction applied on observations of a nearby galaxy, M82, and the compact core of a Galactic molecular cloud, Sgr B2.