Source author record

Georgia Pierrou

Georgia Pierrou appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
2topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

A Data-Driven Energy Storage System-Based Algorithm for Monitoring the Small-Signal Stability of Power Grids with Volatile Wind Power

In this paper, we propose a data-driven energy storage system (ESS)-based method to enhance the online small-signal stability monitoring of power networks with high penetration of intermittent wind power. To accurately estimate inter-area modes that are closely related to the system's inherent stability characteristics, a novel algorithm that leverages on recent advances in wide-area measurement systems (WAMSs) and ESS technologies is developed. It is shown that the proposed approach can smooth the wind power fluctuations in near real-time using a small additional ESS capacity and thus significantly enhance the monitoring of small-signal stability. Dynamic Monte Carlo simulations on the IEEE 68-bus system are used to illustrate the effectiveness of the proposed algorithm in smoothing wind power and estimating the inter-area mode statistical properties.

preprint2021arXiv

An Online Network Model-Free Wide-Area Voltage Control Method Using PMUs

This paper proposes a novel online measurement-based Wide-Area Voltage Control (WAVC) method using Phasor Measurement Unit (PMU) data in power systems with Flexible AC Transmission System (FACTS) devices. As opposed to previous WAVC methods, the proposed WAVC does not require any model knowledge or the participation of all buses and considers both active and reactive power perturbations. Specifically, the proposed WAVC method exploits the regression theorem of the Ornstein-Uhlenbeck process to estimate the sensitivity matrices through PMU data online, which are further used to design and apply the voltage regulation by updating the reference points of FACTS devices. Numerical results on the IEEE 39- Bus and IEEE 68-Bus systems demonstrate that the proposed model-free WAVC can provide effective voltage control in various network topologies, different combinations of voltage-controlled and voltage-uncontrolled buses, under measurement noise, and in case of missing PMUs. Particularly, the proposed WAVC algorithm may outperform the model-based WAVC when an undetected topology change happens.

preprint2021arXiv

Targeted False Data Injection Attack against DC State Estimation without Line Parameters

A novel false data injection attack (FDIA) model against DC state estimation is proposed, which requires no network parameters and exploits only limited phasor measurement unit (PMU) data. The proposed FDIA model can target specific states and launch large deviation attacks using estimated line parameters. Sufficient conditions for the proposed method are also presented. Different attack vectors are studied in the IEEE 39-bus system, showing that the proposed FDIA method can successfully bypass the bad data detection (BDD) with high success rates of up to 95.3%.

preprint2020arXiv

Online PMU-Based Method for Estimating Dynamic Load Parameters in Ambient Conditions

This paper proposes a novel purely measurement-based method for estimating dynamic load parameters in near real-time when stochastic load fluctuations are present. By leveraging on the regression theorem for the Ornstein-Uhlenbeck process, the proposed method can provide highly accurate estimation without requiring any information about the power system model. Furthermore, by exploiting recursion, an online algorithm is developed to estimate the dynamic load parameters in near real-time. Simulation studies on the IEEE 39-Bus system demonstrate the accuracy of the model-free method, its robustness against measurement noise, as well as its satisfactory performance in tracking real-time changes of the load parameters.