Source author record

Gennaro Vitucci

Gennaro Vitucci appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

A predictive microstructure-based approach for the anisotropic damage, residual stretches and hysteresis in biodegradable sutures

We propose a predictive model for the mechanical behavior of biodegradable polymers of interest for biomedical applications. Starting from a detailed description of the network behavior of the copolymer material, taking care of bonds breaking and recrosslinking effects, folded-unfolded transitions and network topological constraints, we deduce a macroscopic law for the complex mechanical behavior of many biomedical materials with a particular focus on absorbable suture threads and a perspective to new material design. A crucial novelty of the model is the careful description of the observed microscopic anisotropic damage induced by the deformation, here described based on the classical microsphere integration approach. The resulting energy, characterized by a few number of material parameters, with physically clear interpretation, is successfully adopted to predict our cyclic experiments on poliglecaprone sutures with anisotropic damage, permanent stretch and internal hysteresis. By also studying other suture materials behavior we show that the predictivity properties of the model can be extended also to materials with a different mechanical response and thus also possibly applied for the design of new, high-performance biomedical materials.

preprint2016arXiv

Three-dimensional contact of TITH cartilage layers, a closed-form solution

Inhomogeneity and anisotropy play a crucial role in attributing articular cartilage its properties. The frictionless contact model constructed here consists in two thin biphasic transversely isotropic transversely homogeneous (TITH) cartilage layers firmly attached onto rigid substrates and shaped as elliptic paraboloids of different radii. Using asymptotic techniques, a solution to the deformation problem of such material has been recently obtained extending previous ones referred to homogeneous materials. The layer itself is thin in comparison with the size of the contact area and the observed time is shorter than the hydrogel characteristic time. The emerging three-dimensional contact problem is solved in closed-form and numerical benchmarks for constant and oscillating loads are given. The results are shown in terms of contact pressure and approach of the bones. The latter is derived to be directly proportional to the contact area. Existing experimental data are reinterpreted in view of the current model formulation. Comparisons are made with existing solutions for homogeneous biphasic materials in order to underline the functional importance of inhomogeneity in spreading the contact pressure distribution across the contact area. Particular attention is paid to the applicability of the retrieved formulas for interpreting measurements of in vivo experiments. Future directions are also prospected.

preprint2015arXiv

An asymptotic model for the deformation of a transversely isotropic, transversely homogeneous biphasic cartilage layer

In the present paper, an asymptotic model is constructed for the short-time deformation of an articular cartilage layer modeled as transversely isotropic, transversely homogeneous (TITH) biphasic material. It is assumed that the layer thickness is relatively small compared with the characteristic size of the normal surface load applied to the upper surface of the cartilage layer, while the bottom surface is assumed to be firmly attached to a rigid impermeable substrate. In view of applications to articular contact problems it is assumed that the interstitial fluid is not allowed to escape through the articular surface.

preprint2015arXiv

Analysis of residual stresses in thermoelastic multilayer cylinders

The topic faced here is the modeling of an axisymmetric multilayer structure. An exact analytical formulation is proposed in the framework of the plane strain problem for a cylinder encircled by annular layers. Isotropic linear thermoelastic materials constitute the body. Perfect and imperfect contacts between the layers are made available for the analysis. The derived exact solution is compared to finite element simulations. Numerical applications are shown in order to study the dependency of the residual stress distribution on the constituent material properties during a cooling process. The role of residual stresses in brittle materials, particularly ceramics, is discussed.