Source author record

Ganesh Natarajan

Ganesh Natarajan appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2023arXiv

Estimation of thermal load on the nozzle base plate from small plumes at high temperature

A numerical study is performed to estimate thermal load on the nozzle base plate, which is in the upstream direction to the flow, from three hot plumes of pure (CO2), (H2O) and 50-50 (%) composition of (CO2) and (H2O) expanding through a convergent-divergent (CD) nozzle in a quiescent medium at 1.1 bar pressure and 298K temperature. The base plate of the nozzle heats up due to thermal radiation, emitting from the hot gases in the form of plumes. The spectral radiative properties of major participating gases such as (CO2), (H2O) are calculated from HITEMP-2010 database. A small CD nozzle which is designed for the perfect expansion of air by 1D calculation with nozzle throat diameter 1.98 mm and area ratio 1.5942, is considered as the design of nozzle for present study [1]. All three plumes are in the under-expanded state for this CD nozzle and hence expands rapidly at supersonic speed as the plumes exit from the nozzle and forms a series of expansion and compression waves. The hot plumes emanating from the nozzle develop very high temperature in a small vicinity around the base plate, due to diffusion and develop very high temperature on the base plate. Barring this region, the maximum amount of radiative flux on base plate for these three plumes, i.e., CO2 plume, mixture plume and H2O plume are 4000 W/m2, 2300 W/m2 and 1300 W/m2, respectively and the maximum temperature developed due to these corresponding fluxes are 323 K, 312 K and 308 K, respectively.

preprint2022arXiv

Numerical analysis of turbulent forced convection and fluid flow past a triangular cylinder with control plate using standard $κ$-$ε$ model

Turbulent flow past an equilateral triangular cylinder with splitter plate inserted downstream is numerically tested for different gap ratios (0, 0.5, 1, 1.5, 2) and plate dimensions (0, 1, 1.5) on the flow field and heat transfer characteristics. Unsteady flow simulations are carried out at Re=22,000 in a finite volume based collocated framework, on a two-dimensional unstructured mesh. Reynolds averaged momentum and energy equations are solved in conjunction with the standard $κ$-$ε$ model. In this study, cylinder and control plate are subjected to constant wall temperature. It is observed that the drag force on the triangular cylinder-splitter plate system reduced with an increase in gap ratio. Vortex shedding is suppressed as Strouhal number (St) reduced to its least value for the maximum gap-ratio configuration studied. Heat transfer performance is also significantly improved with the inclusion of a finite gap. In addition to that, the effect of variation in length of the splitter plate has also been studied on the force coefficients, Strouhal number, local and surface averaged Nusselt number. Results show that increasing the length of the splitter plate significantly suppressed the shedding with a minimum frequency obtained for the maximum plate length of Ls/h = 1.5. However, overall heat transfer reduced with the increase in plate length.