Researcher profile

Gaetano Scamarcio

Gaetano Scamarcio contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Why a diffusing single-molecule can be detected in few minutes by a large capturing bioelectronic interface

Single-molecule detection at a nanometric interface in a femtomolar solution, can take weeks as the encounter rate between the diffusing molecule to be detected and the transducing nano-device is negligibly small. On the other hand, several experiments prove that macroscopic label-free sensors based on field-effect-transistors (FET), engaging micrometric or millimetric detecting interfaces are capable to assay a single-molecule in a large volume within few minutes. The present work demonstrates why at least a single molecule out of a few diffusing in a 100 ul volume has a very high probability to hit a large capturing and detecting electronic interface. To this end, sensing data, measured with an electrolyte-gated FET whose gate is functionalized with 1012 capturing anti-immunoglobulin G, are here provided along with a Brownian diffusion-based modelling. The EG-FET assays solutions down to some tens of zM in concentrations with volumes ranging from 25 ul to 1 ml in which the functionalized gates are incubated for times ranging from 30 s to 20 min.

preprint2011arXiv

Comparative analysis of resonant phonon THz quantum cascade lasers

We present a comparative analysis of a set of GaAs-based THz quantum cascade lasers, based on longitudinal-optical phonon scattering depopulation, by using an ensemble Monte Carlo simulation, including both carrier-carrier and carrier-phonon scattering. The simulation shows that the parasitic injection into the states below the upper laser level limits the injection efficiency and thus the device performance at the lasing threshold. Additional detrimental effects playing an important role are identified. The simulation results are in reasonable agreement with the experimental findings.