Source author record

Gaetano Frascella

Gaetano Frascella appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Broadening the high sensitivity range of squeezing-assisted interferometers by means of two-channel detection

For a squeezing-enhanced SU(2) interferometer, we theoretically investigate the possibility to broaden the phase range of sub-shot-noise sensitivity. We show that this goal can be achieved by implementing detection in both output ports, with the optimal combination of the detectors outputs, leading to a phase sensitivity independent of the interferometer operation point. Provided that each detector is preceded by a phase-sensitive amplifier, this sensitivity could be also tolerant to the detection loss.

preprint2020arXiv

Optical Coherence Tomography with a nonlinear interferometer in the high parametric gain regime

We demonstrate optical coherence tomography based on an SU(1,1) nonlinear interferometer with high-gain parametric down-conversion. For imaging and sensing applications, this scheme promises to outperform previous experiments working at low parametric gain, since higher photon fluxes provide lower integration times for obtaining high-quality images. In this way one can avoid using single-photon detectors or CCD cameras with very high sensitivities, and standard spectrometers can be used instead. Other advantages are: higher sensitivity to small loss and amplification before detection, so that the detected light power considerably exceeds the probing one.

preprint2019arXiv

Experimental reconstruction of spatial Schmidt modes for a wide-field SU(1,1) interferometer

We study the spatial mode content at the output of a wide-field SU(1,1) interferometer, i.e. a nonlinear interferometer comprising two coherently-pumped spatially-multimode optical parametric amplifiers placed in sequence with a focusing element in between. This device is expected to provide a phase sensitivity below the shot-noise limit for multiple modes over a broad angular range. To reconstruct the spatial modes and their weights, we implement a simple method based on the acquisition of only intensity distributions. The eigenmode decomposition of the field is obtained through the measurement of the covariance of intensities at different spatial points. We investigate both the radial and azimuthal (orbital angular momentum) modes and show that their total number is large enough to enable applications of the interferometer in spatially-resolved phase measurements.