Researcher profile

G. Cerizza

G. Cerizza contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Charged particle track reconstruction with S$π$RIT Time Projection Chamber

In this paper, we present a software framework, S$π$RITROOT, which is capable of track reconstruction and analysis of heavy-ion collision events recorded with the S$π$RIT time projection chamber. The track-fitting toolkit GENFIT and the vertex reconstruction toolkit RAVE are applied to a box-type detector system. A pattern recognition algorithm which performs helix track finding and handles overlapping pulses is described. The performance of the software is investigated using experimental data obtained at the Radioactive Isotope Beam Facility (RIBF) at RIKEN. This work focuses on data from $^{132}$Sn + $^{124}$Sn collision events with beam energy of 270 AMeV. Particle identification is established using $\left<dE/dx\right>$ and magnetic rigidity, with pions, hydrogen isotopes, and helium isotopes.

preprint2020arXiv

Particle decays of levels in $^{11,12}$N and $^{12}$O investigated with the invariant-mass method

Particle-decaying states of the light nuclei $^{11,12}$N and $^{12}$O were studied using the invariant-mass method. The decay energies and intrinsic widths of a number of states were measured, and the momentum correlations of three-body decaying states were considered. A second 2$p$-decaying 2$^+$ state of $^{12}$O was observed for the first time, and a higher energy $^{12}$O state was observed in the 4$p$+2$α$ decay channel. This 4$p$+2$α$ channel also contains contributions from fission-like decay paths, including $^6$Be$_{g.s.}$+$^{6}$Be$_{g.s.}$. Analogs to these states in $^{12}$O were found in $^{12}$N in the 2$p$+$^{10}$B and 2$p$+$α$+$^6$Li channels. The momentum correlations for the prompt 2$p$ decay of $^{12}$O$_{g.s.}$ were found to be nearly identical to those of $^{16}$Ne$_{g.s.}$, and the correlations for the new 2$^+$ state were found to be consistent with sequential decay through excited states in $^{11}$N. The momentum correlations for the 2$^+_1$ state in $^{12}$O provide a new value for the $^{11}$N ground-state energy. The states in $^{12}$N/$^{12}$O that belong to the $A$=12 isobaric sextet do not deviate from the quadratic isobaric multiplet mass equation (IMME) form.

preprint2020arXiv

Space Charge Effects in the S$π$RIT Time Projection Chamber

Time projection chambers (TPCs) are widely used in nuclear and particle physics. They are particularly useful when measuring reaction products from heavy ion collisions. Most nuclear experiments at low energy are performed in a fixed target configuration, in which the unreacted beam will pass through the detection volume. As the beam intensity increases, the buildup of positive ions created from the ionization of the detector gas by the beam creates the main source of space charge, distorting the nominal electric field of the TPC. This has a profound effect on the accuracy of the measured momenta of the emitted particles. In this paper we will discuss the magnitude of the effects and construct an observable more appropriate for fixed target experiments to study the effects. We also will present an algorithm for correcting the space charge and some of the implications it has on the momentum determination.

preprint2019arXiv

Development of a novel MPGD-based drift chamber for the NSCL/FRIB S800 spectrometer

The performance of a novel tracking detector developed for the focal plane of the NSCL/FRIB S800 magnetic spectrometer is presented. The detector comprises a large-area drift chamber equipped with a hybrid Micro-Pattern Gaseous Detector (MPGD)-based readout. The latter consists of a position-sensitive Micromegas detector preceded by a two-layer M-THGEM multiplier as a pre-amplification stage. The signals from the Micromegas readout are processed by a data acquisition system based on the General Electronics for TPC (GET). The drift chamber has an effective area of around 60x30 cm^2, which matches to the very large acceptance of the S800 spectrometer. This work discusses in detail the results of performance evaluation tests carried out with a low-energy alpha-particles source and with high-energy heavy-ion beams with the detector installed at the S800 focal plane. In this latter case, the detector was irradiated with a 150 MeV/u 78Kr36+ beam as well as a heavy-ion fragmentation cocktail beam produced by the 78Kr36+ beam impinging on a thin beryllium target. Sub-millimeter position resolution is obtained in both dispersive and non-dispersive directions.