Researcher profile

Fumihiro Uraguchi

Fumihiro Uraguchi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2016arXiv

The Infrared Imaging Spectrograph (IRIS) for TMT: Prototyping of cryogenic compatible stage for the Imager

The IRIS Imager requires opt-mechanical stages which are operable under vacuum and cryogenic environment. Also the stage for the IRIS Imager is required to survive for 10 years without maintenance. To achieve these requirements, we decided prototyping of a two axis stage with 80 mm clear aperture. The prototype was designed as a double-deck stage, upper rotary stage and lower linear stage. Most of components are selected to take advantage of heritage from existing astronomical instruments. In contrast, mechanical components with lubricants such as bearings, linear motion guides and ball screws were modified to survive cryogenic environment. The performance proving test was carried out to evaluate errors such as wobbling, rotary and linear positioning error. We achieved 0.002 $\rm deg_{rms}$ wobbling, 0.08 $\rm deg_{0-p}$ rotational positioning error and 0.07 $\rm mm_{0-p}$ translational positioning error. Also durability test under anticipated load condition has been conducted. In this article, we report the detail of mechanical design, fabrication, performance and durability of the prototype.

preprint2015arXiv

Properties of Weak Lensing Clusters Detected on Hyper Suprime-Cam 2.3 Square Degree Field

We present properties of moderately massive clusters of galaxies detected by the newly developed Hyper Suprime-Cam on the Subaru telescope using weak gravitational lensing. Eight peaks exceeding a S/N ratio of 4.5 are identified on the convergence S/N map of a 2.3 square degree field observed during the early commissioning phase of the camera. Multi-color photometric data is used to generate optically selected clusters using the CAMIRA algorithm. The optical cluster positions were correlated with the peak positions from the convergence map. All eight significant peaks have optical counterparts. The velocity dispersion of clusters are evaluated by adopting the Singular Isothemal Sphere (SIS) fit to the tangential shear profiles, yielding virial mass estimates, M500c, of the clusters which range from 2.7x10^13 to 4.4x10^14 solar mass. The number of peaks is considerably larger than the average number expected from LambdaCDM cosmology but this is not extremely unlikely if one takes the large sample variance in the small field into account. We could, however, safely argue that the peak count strongly favours the recent Planck result suggesting high sigma8$value of 0.83. The ratio of stellar mass to the dark matter halo mass shows a clear decline as the halo mass increases. If the gas mass fraction, fg, in halos is universal, as has been suggested in the literature, the observed baryon mass in stars and gas shows a possible deficit compared with the total baryon density estimated from the baryon oscillation peaks in anisotropy of the cosmic microwave background.

preprint2014arXiv

The Infrared Imaging Spectrograph (IRIS) for TMT: Instrument Overview

We present an overview of the design of IRIS, an infrared (0.84 - 2.4 micron) integral field spectrograph and imaging camera for the Thirty Meter Telescope (TMT). With extremely low wavefront error (<30 nm) and on-board wavefront sensors, IRIS will take advantage of the high angular resolution of the narrow field infrared adaptive optics system (NFIRAOS) to dissect the sky at the diffraction limit of the 30-meter aperture. With a primary spectral resolution of 4000 and spatial sampling starting at 4 milliarcseconds, the instrument will create an unparalleled ability to explore high redshift galaxies, the Galactic center, star forming regions and virtually any astrophysical object. This paper summarizes the entire design and basic capabilities. Among the design innovations is the combination of lenslet and slicer integral field units, new 4Kx4k detectors, extremely precise atmospheric dispersion correction, infrared wavefront sensors, and a very large vacuum cryogenic system.