Source author record

Favio Bortoletto

Favio Bortoletto appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2010arXiv

Autonomous Observations in Antarctica with AMICA

The Antarctic Multiband Infrared Camera (AMICA) is a double channel camera operating in the 2-28 micron infrared domain (KLMNQ bands) that will allow to characterize and exploit the exceptional advantages for Astronomy, expected from Dome C in Antarctica. The development of the camera control system is at its final stage. After the investigation of appropriate solutions against the critical environment, a reliable instrumentation has been developed. It is currently being integrated and tested to ensure the correct execution of automatic operations. Once it will be mounted on the International Robotic Antarctic Infrared Telescope (IRAIT), AMICA and its equipment will contribute to the accomplishment of a fully autonomous observatory.

preprint2000arXiv

Preliminary design of a NIR prime focus corrector for the Galileo Telescope

In this paper a preliminary design for a prime focus corrector to be mounted at the Telescopio Nazionale Galileo (TNG) is presented. The telescope is located on La Palma (Canary Islands) and has a primary mirror of 3.5 m with a hyperbolic sag. Two optical designs have been considered in order to exploit detectors with 1k x 1k and 2k x 2k pixels. Each design makes use of four lenses, two of which are aspherical. The first lens diameters are, respectively, of 140 mm and 320 mm for the two kind of detectors. For both designs the telescope pupil is deliberately not re-imaged, and therefore it will not be possible to insert a cold stop. For such a reason particular care has been dedicated to the telescope thermal background study, in order to optimise the baffling system. The optics is able to correct fields of 11' x 11' and of 60'x60', depending on the design. It should be considered that the particular geometry of the focal plane array mosaic does not permit a full exploitation of the entire field, being based on a combination of four detectors. The selected chips are HgCdTe manufactured by Rockwell, i.e. Hawaii I in the 1k x 1k case and Hawaii II in the 2k x 2k case.