Researcher profile

F. R. Harnden, Jr.

F. R. Harnden, Jr. contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2004arXiv

Chandra Orion Ultradeep Project: Observations and Source Lists

We present a description of the data reduction methods and the derived catalog of more than 1600 X-ray point sources from the exceptionally deep January 2003 Chandra X-ray Observatory observation of the Orion Nebula Cluster and embedded populations around OMC-1. The observation was obtained with Chandra's Advanced CCD Imaging Spectrometer (ACIS) and has been nicknamed the Chandra Orion Ultradeep Project (COUP). With an 838 ks exposure made over a continuous period of 13.2 days, the COUP observation provides the most uniform and comprehensive dataset on the X-ray emission of normal stars ever obtained in the history of X-ray astronomy.

preprint2004arXiv

X-ray spectroscopy of the unsteady quiescent corona of AD Leo with Chandra

We present the analysis and interpretation of an observation of the flare star AD Leo (dM3e) with Chandra/LETG. The high resolution X-ray spectrum allowed us to infer the plasma emission measure distribution (EMD) vs. temperature, and the abundances of individual elements in the corona of this magnetically-active star, during a typical state characterized by significant variability but no large flaring event. We have also measured plasma densities at various temperatures using spectroscopic diagnostics provided by He-like triplets and Fe XXI lines. We show that the present EMD is similar to those previously obtained from EUVE spectra during quiescent and flaring states, confirming the long-term stability of the corona of AD Leo. At variance with the case of other active stars, the EMD of AD Leo is characterized by a significantly shallower slope, compatible with that predicted by static models of isobaric loops with constant cross-section and uniform heating. We discuss such coronal modeling to infer the average properties of the corona in terms of loop populations, including estimates of the surface filling factor. We also show that the EMD is compatible with the model of a corona continuously heated by flares. The coronal composition is such that the element abundances, relative to solar values, tend to increase with the First Ionization Potential, with few exceptions. The line to continuum ratios suggest a nearly solar coronal metallicity.

preprint2003arXiv

Chandra Multi-wavelength Project (ChaMP). I. First X-ray Source Catalog

The Chandra Multi-wavelength Project (ChaMP) is a wide-area (~14 deg^2) survey of serendipitous Chandra X-ray sources, aiming to establish fair statistical samples covering a wide range of characteristics (such as absorbed AGNs, high z clusters of galaxies) at flux levels (fX ~ 10^-15 - 10^-14 erg sec-1 cm-2) intermediate between the Chandra Deep surveys and previous missions. We present the first ChaMP catalog, which consists of 991 near on-axis, bright X-ray sources obtained from the initial sample of 62 observations. The data have been uniformly reduced and analyzed with techniques specifically developed for the ChaMP and then validated by visual examination. To assess source reliability and positional uncertainty, we perform a series of simulations and also use Chandra data to complement the simulation study. The false source detection rate is found to be as good as or better than expected for a given limiting threshold. On the other hand, the chance of missing a real source is rather complex, depending on the source counts, off-axis distance (or PSF), and background rate. The positional error (95% confidence level) is usually < 1&#34; for a bright source, regardless of its off-axis distance while it can be as large as 4&#34; for a weak source (~20 counts) at a large off-axis distance (Doff-axis > 8&#39;). We have also developed new methods to find spatially extended or temporary variable sources and those sources are listed in the catalog.

preprint2003arXiv

Chandra Multi-wavelength Project (ChaMP). II. First Results of X-ray Source Properties

We present the first results of ChaMP X-ray source properties obtained from the initial sample of 62 observations. The data have been uniformly reduced and analyzed with techniques specifically developed for the ChaMP and then validated by visual examination. Utilizing only near on-axis, bright X-ray sources (to avoid problems caused by incompleteness and the Eddington bias), we derive the Log(N)-Log(S) relation in soft (0.5-2 keV) and hard (2-8 keV) energy bands. The ChaMP data are consistent with previous results of ROSAT, ASCA and Chandra deep surveys. In particular, our data nicely fill in the flux gap in the hard band between the Chandra Deep Field data and the previous ASCA data. We check whether there is any systematic difference in the source density between cluster and non-cluster fields and also search for field-to-field variations, both of which have been previously reported. We found no significant field-to-field cosmic variation in either test within the statistics (~1 sigma) across the flux levels included in our sample. In the X-ray color-color plot, most sources fall in the location characterized by photon index = 1.5-2 and NH = a few x 10^20 cm^2, suggesting that they are typical broad-line AGNs. There also exist a considerable number of sources with peculiar X-ray colors (e.g., highly absorbed, very hard, very soft). We confirm a trend that on average the X-ray color hardens as the count rate decreases. Since the hardening is confined to the softest energy band (0.3-0.9 keV), we conclude it is most likely due to absorption. We cross-correlate the X-ray sources with other catalogs and describe their properties in terms of optical color, X-ray-to-optical luminosity ratio and X-ray colors.