Researcher profile

F. Perfetto

F. Perfetto contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2025arXiv

Control and read-out of the HEPD-02 tracking system onboard CSES-02 satellite

The High Energy Particle Detector (HEPD-02) is a payload of the second China Seismo-Electromagnetic Satellite (CSES-02), designed and built by the Italian Limadou collaboration. Its purpose is to detect cosmic rays and trapped particles of radiation belts, in the kinetic energy range 3-100 MeV for electrons, 30-200 MeV for protons. HEPD-02 is the first space detector to use a tracking detector based on Monolithic Active Pixel Sensors (MAPS). The MAPS provides high spatial resolution, low noise, increased robustness, and low production costs. Operating MAPS in space presents a significant challenge due to strict power consumption requirements. To meet such constraints, a custom Tracker Data Acquisition (TDAQ) board and firmware have been designed and implemented, by using a commercial low-power Field Programmable Gate Array (FPGA). This paper addresses the design features of the TDAQ unit, enabling the tracking detector to be operated efficiently, with particular focus on the power consumption performance.

preprint2013arXiv

Light Yield in DarkSide-10: a Prototype Two-phase Liquid Argon TPC for Dark Matter Searches

As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-recoil backgrounds by pulse shape discrimination. We have measured the light yield of DarkSide-10 using the readily-identifiable full-absorption peaks from gamma ray sources combined with single-photoelectron calibrations using low-occupancy laser pulses. For gamma lines of energies in the range 122-1275 keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys) p.e./keVee. With additional purification, the light yield measured at 511 keV increased to 9.142+-0.006(stat) p.e./keVee.

preprint2013arXiv

VUV-Vis optical characterization of Tetraphenyl-butadiene films on glass and specular reflector substrates from room to liquid Argon temperature

The use of efficient wavelength-shifters from the vacuum-ultraviolet to the photosensor's range of sensitivity is a key feature in detectors for Dark Matter search and neutrino physics based on liquid argon scintillation detection. Thin film of Tetraphenyl-butadiene (TPB) deposited onto the surface delimiting the active volume of the detector and/or onto the photosensor optical window is the most common solution in current and planned experiments. Detector design and response can be evaluated and correctly simulated only when the properties of the optical system in use (TPB film + substrate) are fully understood. Characterization of the optical system requires specific, sometimes sophisticated optical methodologies. In this paper the main features of TPB coatings on different, commonly used substrates is reported, as a result of two independent campaigns of measurements at the specialized optical metrology labs of ENEA and University of Tor Vergata. Measured features include TPB emission spectra with lineshape and relative intensity variation recorded as a function of the film thickness and for the first time down to LAr temperature, as well as optical reflectance and transmittance spectra of the TPB coated substrates in the wavelength range of the TPB emission.

preprint2012arXiv

Search for "anomalies" from neutrino and anti-neutrino oscillations at Delta_m^2 ~ 1eV^2 with muon spectrometers and large LAr-TPC imaging detectors

This proposal describes an experimental search for sterile neutrinos beyond the Standard Model with a new CERN-SPS neutrino beam. The experiment is based on two identical LAr-TPC's followed by magnetized spectrometers, observing the electron and muon neutrino events at 1600 and 300 m from the proton target. This project will exploit the ICARUS T600, moved from LNGS to the CERN "Far" position. An additional 1/4 of the T600 detector will be constructed and located in the "Near" position. Two spectrometers will be placed downstream of the two LAr-TPC detectors to greatly complement the physics capabilities. Spectrometers will exploit a classical dipole magnetic field with iron slabs, and a new concept air-magnet, to perform charge identification and muon momentum measurements in a wide energy range over a large transverse area. In the two positions, the radial and energy spectra of the nu_e beam are practically identical. Comparing the two detectors, in absence of oscillations, all cross sections and experimental biases cancel out, and the two experimentally observed event distributions must be identical. Any difference of the event distributions at the locations of the two detectors might be attributed to the possible existence of ν-oscillations, presumably due to additional neutrinos with a mixing angle sin^2(2theta_new) and a larger mass difference Delta_m^2_new. The superior quality of the LAr imaging TPC, in particular its unique electron-pi_zero discrimination allows full rejection of backgrounds and offers a lossless nu_e detection capability. The determination of the muon charge with the spectrometers allows the full separation of nu_mu from anti-nu_mu and therefore controlling systematics from muon mis-identification largely at high momenta.

preprint2012arXiv

Search for anomalies in the neutrino sector with muon spectrometers and large LArTPC imaging detectors at CERN

A new experiment with an intense ~2 GeV neutrino beam at CERN SPS is proposed in order to definitely clarify the possible existence of additional neutrino states, as pointed out by neutrino calibration source experiments, reactor and accelerator experiments and measure the corresponding oscillation parameters. The experiment is based on two identical LAr-TPCs complemented by magnetized spectrometers detecting electron and muon neutrino events at Far and Near positions, 1600 m and 300 m from the proton target, respectively. The ICARUS T600 detector, the largest LAr-TPC ever built with a size of about 600 ton of imaging mass, now running in the LNGS underground laboratory, will be moved at the CERN Far position. An additional 1/4 of the T600 detector (T150) will be constructed and located in the Near position. Two large area spectrometers will be placed downstream of the two LAr-TPC detectors to perform charge identification and muon momentum measurements from sub-GeV to several GeV energy range, greatly complementing the physics capabilities. This experiment will offer remarkable discovery potentialities, collecting a very large number of unbiased events both in the neutrino and antineutrino channels, largely adequate to definitely settle the origin of the observed neutrino-related anomalies.

preprint2011arXiv

Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature

Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photo multiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these testes the Hamamatsu PMTs showed superb performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.

preprint2010arXiv

Measurement of the $η\to 3π^{0}$ slope parameter $α$ with the KLOE detector

We present a measurement of the slope parameter $α$ for the $η\to 3π^{0}$ decay, with the KLOE experiment at the DA$Φ$NE $ϕ$-factory, based on a background free sample of $\sim$ 17 millions $η$ mesons produced in $ϕ$ radiative decays. By fitting the event density in the Dalitz plot we determine $α= -0.0301 \pm 0.0035\,stat\;_{-0.0035}^{+0.0022}\,syst\,$. The result is in agreement with recent measurements from hadro- and photo-production experiments.

preprint2009arXiv

Measurement of the branching ratio and search for a CP violating asymmetry in the eta -> pi+pi-e+e-(gamma) decay at KLOE

We have studied the eta->pi+pi-e+e-(gamma) decay using about 1.7 fb^-1 collected by the KLOE experiment at the DAFNE phi-factory. This corresponds to about 72 millions eta mesons produced in phi radiative decays. We have measured the branching ratio, inclusive of radiative effects, with 4% accuracy: BR(eta->pi+pi-e+e-(gamma)) = (26.8 +/- 0.9_Stat. +/- 0.7_Syst.) x 10^-5. We have obtained the first measurement of the CP-odd pipi-ee decay planes angular asymmetry, A_phi = (-0.6 +/- 2.5_Stat. +/- 1.8_Syst.) x 10^-2.

preprint2009arXiv

Search for the K_S -> e+e- decay with the KLOE detector

We present the result of a direct search for the decay K_S -> e+e-, obtained with a sample of e+e- -> phi -> K_S K_L events produced at DAFNE, the Frascati phi-factory, for an integrated luminosity of 1.9 fb^-1. The search has been performed using a pure K_S beam tagged by the simultaneous detection of a K_L interaction in the calorimeter. Background rejection has been optimized by using both kinematic and particle identification cuts. We find BR(K_S -> e+e-) < 9x10^-9 at 90% CL, which improves by an order of magnitude on the previous best limit.

preprint2009arXiv

Study of the a_0(980) meson via the radiative decay phi->eta pi^0 gamma with the KLOE detector

We have studied the phi->a_0(980) gamma process with the KLOE detector at the Frascati phi-factory DAPhNE by detecting the phi->eta pi^0 gamma decays in the final states with eta->gamma gamma and eta->pi^+ pi^- pi^0. We have measured the branching ratios for both final states: Br(phi->eta pi^0 gamma)=(7.01 +/- 0.10 +/- 0.20)x10^-5 and (7.12 +/- 0.13 +/- 0.22)x10^-5 respectively. We have also extracted the a_0(980) mass and its couplings to eta pi^0, K^+ K^-, and to the phi meson from the fit of the eta pi^0 invariant mass distributions using different phenomenological models.