Researcher profile

Evan Kress

Evan Kress contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Liger at Keck Observatory: Design of Imager Optical Assembly and Spectrograph Re-Imaging Optics

Liger is an adaptive optics (AO) fed imager and integral field spectrograph (IFS) designed to take advantage of the Keck All-sky Precision Adaptive-optics (KAPA) upgrade for the W.M. Keck Observatory. We present the design and analysis of the imager optical assembly including the spectrograph Re-Imaging Optics (RIO) which transfers the beam path from the imager focal plane to the IFS slicer module and lenslet array. Each imager component and the first two RIO mechanisms are assembled and individually aligned on the same optical plate. Baffling suppresses background radiation and scattered light, and a pupil viewing camera allows the imager detector to focus on an image of the telescope pupil. The optical plate mounts on an adapter frame for alignment of the overall system. The imager and RIO will be characterized in a cryogenic test chamber before installation in the final science cryostat.

preprint2022arXiv

Liger at Keck Observatory: Imager Detector and IFS Pick-off Mirror Assembly

Liger is a next-generation near-infrared imager and integral field spectrograph (IFS) planned for the W.M. Keck Observatory. Liger is designed to take advantage of improved adaptive optics (AO) from the Keck All-Sky Precision Adaptive Optics (KAPA) upgrade currently underway. Liger operates at 0.84-2.45 $μ$m with spectral resolving powers of R$\sim$4,000-10,000. Liger makes use of a sequential imager and spectrograph design allowing for simultaneous observations. There are two spectrograph modes: a lenslet with high spatial sampling of 14 and 31 mas, and a slicer with 75 and 150 mas sampling with an expanded field of view. Two pick-off mirrors near the imager detector direct light to these two IFS channels. We present the design and structural analysis for the imager detector and IFS pick-off mirror mounting assembly that will be used to align and maintain stability throughout its operation. A piezoelectric actuator will be used to step through $\rm3\,mm$ of travel during alignment of the instrument to determine the optimal focus for both the detector and pick-off mirrors which will be locked in place during normal operation. We will demonstrate that the design can withstand the required gravitational and shipping loads and can be aligned within the positioning tolerances for the optics.

preprint2014arXiv

The Integral Field Spectrograph for the Gemini Planet Imager

The Gemini Planet Imager (GPI) is a complex optical system designed to directly detect the self-emission of young planets within two arcseconds of their host stars. After suppressing the starlight with an advanced AO system and apodized coronagraph, the dominant residual contamination in the focal plane are speckles from the atmosphere and optical surfaces. Since speckles are diffractive in nature their positions in the field are strongly wavelength dependent, while an actual companion planet will remain at fixed separation. By comparing multiple images at different wavelengths taken simultaneously, we can freeze the speckle pattern and extract the planet light adding an order of magnitude of contrast. To achieve a bandpass of 20%, sufficient to perform speckle suppression, and to observe the entire two arcsecond field of view at diffraction limited sampling, we designed and built an integral field spectrograph with extremely low wavefront error and almost no chromatic aberration. The spectrograph is fully cryogenic and operates in the wavelength range 1 to 2.4 microns with five selectable filters. A prism is used to produce a spectral resolution of 45 in the primary detection band and maintain high throughput. Based on the OSIRIS spectrograph at Keck, we selected to use a lenslet-based spectrograph to achieve an rms wavefront error of approximately 25 nm. Over 36,000 spectra are taken simultaneously and reassembled into image cubes that have roughly 192x192 spatial elements and contain between 11 and 20 spectral channels. The primary dispersion prism can be replaced with a Wollaston prism for dual polarization measurements. The spectrograph also has a pupil-viewing mode for alignment and calibration.