Source author record

E. Tusi

E. Tusi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Linearity and rate capability measurements of RPC with semi-insulating crystalline electrodes operating in avalanche mode

The intrinsic rate capability and the ageing properties of the Resistive Plate Chambers are closely related to the electrodes material and to the front-end electronics threshold. The development of a low noise pre-amplifier led us to improve the intrinsic rate capability of High Pressure Laminate (bakelite) up to $\sim10\;kHz/cm^2$, nevertheless the effective rate is significantly limited by electrodes ageing. To further improve the effective rate capability new materials are investigated. A Resistive Plate Chamber with crystalline semi-insulating Gallium Arsenide electrodes has been characterized with high energy electrons beam at the Beam Test Facility (BFT), (INFN National Laboratory of Frascati, Italy). The response of the Resistive Plate Chamber to multiple bunched electrons was measured operating the detector in avalanche mode. The intrinsic rate capability has been also measured operating the detector in a uniform high energy gamma radiation field at the GIF++ facility (EHN1 of SPS, CERN).

preprint2009arXiv

The Fluorescence Detector of the Pierre Auger Observatory

The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.