Source author record

E. Schilling

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
1topics
4close collaborators

Published work

2 publications

preprint2020arXiv

Study of Two-Photon Exchange via the Beam Transverse Single Spin Asymmetry in Electron-Proton Elastic Scattering at Forward Angles over a Wide Energy Range

We report on a new measurement of the beam transverse single spin asymmetry in electron-proton elastic scattering, A⊥epA^{ep}_{\perp}, at five beam energies from 315.1 MeV to 1508.4 MeV and at a scattering angle of 30∘<θ<40∘30^{\circ} < θ< 40^{\circ}. The covered Q2Q^2 values are 0.032, 0.057, 0.082, 0.218, 0.613 (GeV/c)2^2. The measurement clearly indicates significant inelastic contributions to the two-photon-exchange (TPE) amplitude in the low-Q2Q^2 kinematic region. No theoretical calculation is able to reproduce our result. Comparison with a calculation based on unitarity, which only takes into account elastic and πN\mathrm{πN} inelastic intermediate states, suggests that there are other inelastic intermediate states such as ππN\mathrm{ππN}, KΛ\mathrm{K Λ} and ηN\mathrm{ηN}. Covering a wide energy range, our new high-precision data provide a benchmark to study those intermediate states.

preprint2011arXiv

Realtime calibration of the A4 electromagnetic lead fluoride calorimeter

Sufficient energy resolution is the key issue for the calorimetry in particle and nuclear physics. The calorimeter of the A4 parity violation experiment at MAMI is a segmented calorimeter where the energy of an event is determined by summing the signals of neighbouring channels. In this case the precise matching of the individual modules is crucial to obtain a good energy resolution. We have developped a calibration procedure for our total absorbing electromagnetic calorimeter which consists of 1022 lead fluoride (PbF_2) crystals. This procedure reconstructs the the single-module contributions to the events by solving a linear system of equations, involving the inversion of a 1022 x 1022-matrix. The system has shown its functionality at beam energies between 300 and 1500 MeV and represents a new and fast method to keep the calorimeter permanently in a well-calibrated state.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.