Researcher profile

E. Robert Ligon

E. Robert Ligon contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2022arXiv

Design of the new CHARA instrument SILMARIL: pushing the sensitivity of a 3-beam combiner in the H- and K-bands

Optical interferometry is a powerful technique to achieve high angular resolution. However, its main issue is its lack of sensitivity, compared to other observation techniques. Efforts have been made in the previous decade to improve the sensitivity of optical interferometry, with instruments such as PIONIER and GRAVITY at VLTI, or MIRC-X and MYSTIC at CHARA. While those instruments pushed on sensitivity, their design focus was not the sensitivity but relative astrometric accuracy, imaging capability, or spectral resolution. Our goal is to build an instrument specifically designed to optimize for sensitivity. This meant focusing our design efforts on different parts of the instrument and investigating new technologies and techniques. First, we make use of the low-noise C-RED One camera using e-APD technology and provided by First Light Imaging, already used in the improvement of sensitivity in recent new instruments. We forego the use of single-mode fibers but still favor an image plane design that offers more sensitivity than a pupil plane layout. We also use a minimum number of optical elements to maximize the throughput of the design, using a long focal length cylindrical mirror. We chose to limit our design to 3 beams, to have the capability to obtain closure phases, but not dilute the incoming flux in more beam combinations. We also use in our design an edge filter to have the capability to observe H- and K-band at the same time. We use a low spectral resolution, allowing for group delay fringe tracking but maximizing the SNR of the fringes for each spectral channel. All these elements will lead to a typical limiting magnitude between 10 and 11 in both H- and K-bands.