Researcher profile

Dong Joo Rhee

Dong Joo Rhee contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2026arXiv

Feasibility of a General-Purpose Deep Learning Dose Engine: A Multi-Site Validation Study

Conventional radiotherapy dose calculation algorithms are often computationally slow and non-differentiable, creating bottlenecks for online adaptive radiotherapy (ART) and limiting end-to-end automatic planning. Deep learning provides consistent inference performance and a differentiable framework essential for rapid optimization. In this study, we developed a generalized, site-independent deep learning dose engine using a beamlet-based input strategy. This establishes a computationally consistent and differentiable module that enables end-to-end training for autoplanning while maintaining accuracy across diverse geometries. A dataset of 3,600 plans from 120 patients across six anatomical sites was used to train two 3D convolutional neural networks, a standard U-Net and a Cascade U-Net, to predict 3D dose distributions from CT images and divergent MLC/jaw projections. Performance was validated via 3D gamma analysis on an independent cohort of 60 VMAT plans. The optimal model (U-Net with MAE loss) achieved a mean gamma passing rate of $98.9 \pm 1.6\%$ (3%/2mm, 10% threshold). Performance remained robust across all sites (passing rates $>98\%$), demonstrating that the beamlet-based strategy generalizes effectively to complex geometries without site-specific training. These results indicate that a single, site-independent model can calculate radiotherapy dose distributions with clinical accuracy. This differentiable engine is highly suitable for integration into end-to-end automatic planning, online ART, and secondary dose verification workflows.

preprint2022arXiv

Automated WBRT Treatment Planning via Deep Learning Auto-Contouring and Customizable Landmark-Based Field Aperture Design

In this work, we developed and evaluated a novel pipeline consisting of two landmark-based field aperture generation approaches for WBRT treatment planning; they are fully automated and customizable. The automation pipeline is beneficial for both clinicians and patients, where we can reduce clinician workload and reduce treatment planning time. The customizability of the field aperture design addresses different clinical requirements and allows the personalized design to become feasible. The performance results regarding quantitative and qualitative evaluations demonstrated that our plans were comparable with the original clinical plans. This technique has been deployed as part of a fully automated treatment planning tool for whole-brain cancer and could be translated to other treatment sites in the future.

preprint2022arXiv

Automation of Radiation Treatment Planning for Rectal Cancer

To develop an automated workflow for rectal cancer three-dimensional conformal radiotherapy treatment planning that combines deep-learning(DL) aperture predictions and forward-planning algorithms. We designed an algorithm to automate the clinical workflow for planning with field-in-field. DL models were trained, validated, and tested on 555 patients to automatically generate aperture shapes for primary and boost fields. Network inputs were digitally reconstructed radiography, gross tumor volume(GTV), and nodal GTV. A physician scored each aperture for 20 patients on a 5-point scale(>3 acceptable). A planning algorithm was then developed to create a homogeneous dose using a combination of wedges and subfields. The algorithm iteratively identifies a hotspot volume, creates a subfield, and optimizes beam weight all without user intervention. The algorithm was tested on 20 patients using clinical apertures with different settings, and the resulting plans(4 plans/patient) were scored by a physician. The end-to-end workflow was tested and scored by a physician on 39 patients using DL-generated apertures and planning algorithms. The predicted apertures had Dice scores of 0.95, 0.94, and 0.90 for posterior-anterior, laterals, and boost fields, respectively. 100%, 95%, and 87.5% of the posterior-anterior, laterals, and boost apertures were scored as clinically acceptable, respectively. Wedged and non-wedged plans were clinically acceptable for 85% and 50% of patients, respectively. The final plans hotspot dose percentage was reduced from 121%($\pm$ 14%) to 109%($\pm$ 5%) of prescription dose. The integrated end-to-end workflow of automatically generated apertures and optimized field-in-field planning gave clinically acceptable plans for 38/39(97%) of patients. We have successfully automated the clinical workflow for generating radiotherapy plans for rectal cancer for our institution.