Researcher profile

Derek Kopon

Derek Kopon contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
1topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2010arXiv

An Advanced Atmospheric Dispersion Corrector: The Magellan Visible AO Camera

In addition to the BLINC/MIRAC IR science instruments, the Magellan adaptive secondary AO system will have an EEV CCD47 that can be used both for visible AO science and as a wide-field acquisition camera. The effects of atmospheric dispersion on the elongation of the diffraction limited Magellan adaptive optics system point spread function (PSF) are significant in the near IR. This elongation becomes particularly egregious at visible wavelengths, culminating in a PSF that is 2000\{mu}m long in one direction and diffraction limited (30-60 \{mu}m) in the other over the wavelength band 0.5-1.0\{mu}m for a source at 45\pm zenith angle. The planned Magellan AO system consists of a deformable secondary mirror with 585 actuators. This number of actuators should be sufficient to nyquist sample the atmospheric turbulence and correct images to the diffraction limit at wavelengths as short as 0.7\{mu}m, with useful science being possible as low as 0.5\{mu}m. In order to achieve diffraction limited performance over this broad band, 2000\{mu}m of lateral color must be corrected to better than 10\{mu}m. The traditional atmospheric dispersion corrector (ADC) consists of two identical counter-rotating cemented doublet prisms that correct the primary chromatic aberration. We propose two new ADC designs: the first consisting of two identical counter-rotating prism triplets, and the second consisting of two pairs of cemented counter-rotating prism doublets that use both normal dispersion and anomalous dispersion glass in order to correct both primary and secondary chromatic aberration. The two designs perform 58% and 68%, respectively, better than the traditional two-doublet design. We also present our design for a custom removable wide-field lens that will allow our CCD47 to switch back and forth between an 8.6" FOV for AO science and a 28.5" FOV for acquisition.

preprint2010arXiv

Enabling Technologies for Visible Adaptive Optics: The Magellan Adaptive Secondary VisAO Camera

Since its beginnings, diffraction-limited ground-based adaptive optics (AO) imaging has been limited to wavelengths in the near IR (λ > 1 micron) and longer. Visible AO (λ < 1 micron) has proven to be difficult because shorter wavelengths require wavefront correction on very short spatial and temporal scales. The pupil must be sampled very finely, which requires dense actuator spacing and fine wavefront sampling with large dynamic range. In addition, atmospheric dispersion is much more significant in the visible than in the near-IR. Imaging over a broad visible band requires a very good Atmospheric Dispersion Corrector (ADC). Even with these technologies, our AO simulations using the CAOS code, combined with the optical and site parameters for the 6.5m Magellan telescope, demonstrate a large temporal variability of visible (λ=0.7 micron) Strehl on timescales of 50 ms. Over several hundred milliseconds, the visible Strehl can be as high at 50% and as low as 10%. Taking advantage of periods of high Strehl requires either the ability to read out the CCD very fast, thereby introducing significant amounts of read-noise, or the use of a fast asynchronous shutter that can block the low-Strehl light. Our Magellan VisAO camera will use an advanced ADC, a high-speed shutter, and our 585 actuator adaptive secondary to achieve broadband (0.5-1.0 micron) diffraction limited images on the 6.5m Magellan Clay telescope in Chile at Las Campanas Observatory. These will be the sharpest and deepest visible direct images taken to date with a resolution of 17 mas, a factor of 2.7 better than the diffraction limit of the Hubble Space Telescope.