Researcher profile

Dayne E. Fratanduono

Dayne E. Fratanduono contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Development of slurry targets for high repetition-rate XFEL experiments

Combining an x-ray free electron laser (XFEL) with high power laser drivers enables the study of phase transitions, equation-of-state, grain growth, strength, and transformation pathways as a function of pressure to 100s GPa along different thermodynamic compression paths. Future high-repetition rate laser operation will enable data to be accumulated at >1 Hz which poses a number of experimental challenges including the need to rapidly replenish the target. Here, we present a combined shock-compression and X-ray diffraction study on vol% epoxy(50)-crystalline grains(50) (slurry) targets, which can be fashioned into extruded ribbons for high repetition-rate operation. For shock-loaded NaCl-slurry samples, we observe pressure, density and temperature states within the embedded NaCl grains consistent with observations for shock-compressed single-crystal NaCl.

preprint2021arXiv

Quantitative analysis of diffraction by liquids using a pink-spectrum X-ray source

We describes a new approach for performing quantitative structure-factor analysis and density measurements of liquids using x-ray diffraction with a pink-spectrum x-ray source. The methodology corrects for the pink beam effect by performing a Taylor series expansion of the diffraction signal. The mean density, background scale factor, peak x-ray energy about which the expansion is performed, and the cutoff radius for density measurement are estimated using the derivative-free optimization scheme. The formalism is demonstrated for a simulated radial distribution function for tin. Finally, the proposed methodology is applied to experimental data on shock compressed tin recorded at the Dynamic Compression Sector at the Advanced Photon Source, with derived densities comparing favorably to other experimental results and the equations of state of tin.

preprint2018arXiv

Non-Iterative Characteristics Analysis for High-Pressure Ramp Loading

In the canonical ramp compression experiment, a smoothly-increasing load is applied to the surface of the sample, and the particle velocity history is measured at two or more different distances into the sample, at interfaces where the surface of the sample can be probed. The velocity histories are used to deduce a stress-density relation, usually using iterative Lagrangian analysis to account for the perturbing effect of the impedance mismatch at the interface. In that technique, a stress- density relation is assumed in order to correct for the perturbation, and is adjusted until it becomes consistent with the deduced stress-density relation. This process is subject to the usual difficulties of nonlinear optimization, such as the existence of local minima (sensitivity to the initial guess), possible failure to converge, and relatively large computational effort. We show that, by considering the interaction of successive characteristics reaching the interfaces, the stress-density relation can be deduced directly by recursion rather than iteration. This calculation is orders of magnitude faster than iterative analysis, and does not require an initial guess. Direct recursion may be less suitable for very noisy data, but it was robust when applied to trial data. The stress-density relation deduced was identical to the result from iterative Lagrangian analysis.