Researcher profile

David Alesini

David Alesini contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2015arXiv

DAFNE Consolidation Program and Operation with the KLOE-2 Detector

After a long preparatory phase, including a wide hardware consolidation program, the Italian lepton collider DAFNE, is now systematically delivering data to the KLOE-2 experiment. In approximately 200 days of operation 1 fb-1 has been given to the detector limiting the background to a level compatible with an efficient data acquisition. Instantaneous and maximum daily integrated luminosity measured, so far, are considerably higher with respect to the previous KLOE runs, and are: L(inst) ~ 2.0 1032 cm-2s-1, and L(day) ~ 12.5 pb-1 respectively. A general review concerning refurbishing activities, machine optimization efforts and data taking performances is presented and discussed.

preprint2013arXiv

TE Wave Measurement and Modeling

In the TE wave method, microwaves are coupled into the beam-pipe and the effect of the electron cloud on these microwaves is measured. An electron cloud (EC) density can then be calculated from this measurement. There are two analysis methods currently in use. The first treats the microwaves as being transmitted from one point to another in the accelerator. The second more recent method, treats the beam-pipe as a resonant cavity. This paper will summarize the reasons for adopting the resonant TE wave analysis as well as give examples from CESRTA and DAΦNE of resonant beam-pipe. The results of bead-pull bench measurements will show some possible standing wave patterns, including a cutoff mode (evanescent) where the field decreases exponentially with distance from the drive point. We will outline other recent developments in the TE wave method including VORPAL simulations of microwave resonances, as well as the simulation of transmission in the presence of both an electron cloud and magnetic fields.

preprint2012arXiv

Mitigation and control of instabilities in DAFNE positron ring

The positron beam in the DAFNE e+/e- collider has always been suffering from strong e-cloud instabilities. In order to cope with them, several approaches have been adopted along the years: flexible and powerful bunch-by-bunch feedback systems, solenoids around the straight sections of the vacuum chamber and, in the last runs, e-cloud clearing electrodes inside the bending and wiggler magnets. Of course classic diagnostics tools have been used to evaluate the effectiveness of the adopted measures and the correct setup of the devices, in order to acquire total beam and bunch-by-bunch currents, to plot in real time synchrotron and betatron instabilities, to verify the vertical beam size enlargement in collision and out of collision. Besides, to evaluate the efficacy of the solenoids and of the clearing electrodes versus the instability speed, the more powerful tools have been the special diagnostics routines making use of the bunch-by-bunch feedback systems to quickly compute the growth rate instabilities and the bunch-by-bunch tune spread in different beam conditions.