Source author record

Daniele Zonetti

Daniele Zonetti appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

An Almost Globally Stable Adaptive Phase-Locked Loop for Synchronization of a Grid-Connected Voltage Source Converter

In this paper we are interested in the problem of adaptive synchronization of a voltage source converter with a possibly weak grid with unknown angle and frequency, but knowledge of its parameters. To guarantee a suitable synchronization with the angle of the three-phase grid voltage we design an adaptive observer for such a signal requiring measurements only at the point of common coupling. Then we propose two alternative certainty-equivalent, adaptive phase-locked loops that ensure the angle estimation error goes to zero for almost all initial conditions. Although well-known, for the sake of completeness, we also present a PI controller with feedforward action that ensures the converter currents converge to an arbitrary desired value. Relevance of the theoretical results and their robustness to variation of the grid parameters are thoroughly discussed and validated in the challenging scenario of a converter connected to a grid with low short-circuit-ratio.

preprint2022arXiv

An Observer-Based Composite Identifier for Online Estimation of the Thevenin Equivalent Parameters of a Power System

We consider a Thévenin equivalent circuit capturing the dynamics of a power grid as seen from the point of common coupling with a power electronic converter, and provide a solution to the problem of online identification of the corresponding circuit parameters. For this purpose, we first derive a linear regression model in the conventional abc coordinates and next design a bounded observer-based composite identifier that requires local measurements and knowledge of the grid frequency only. An extension that guarantees exponential convergence of the estimates, under the additional assumption of knowledge of the grid X/R ratio, is further provided. The performance of the proposed identifier, which subsumes a conventional gradient descent algorithm, is illustrated via detailed computer simulations.

preprint2022arXiv

Passivity-based design and analysis of phase-locked loops

We consider a grid-connected voltage source converter (VSC) and address the problem of estimating the grid angle and frequency, information that is essential for an appropriate operation of the converter. We design phase-locked loop (PLL) algorithms with guaranteed stability properties, under the assumption that the grid is characterized by relatively high short-circuit-ratio (SCR) and inertia. In particular we derive, using passivity arguments, generalization of the conventional synchronous reference frame (SRF) and arctangent (ATAN) PLL, which are the standard solutions in power applications. The analysis is further extended to the case of connection of the VSC to a low-inertia grid, ensuring robustness of the algorithms in case of frequency variations. The results are validated on a benchmark including the grid, the VSC and related controllers.

preprint2016arXiv

A survey on modeling of microgrids - from fundamental physics to phasors and voltage sources

Microgrids have been identified as key components of modern electrical systems to facilitate the integration of renewable distributed generation units. Their analysis and controller design requires the development of advanced (typically model-based) techniques naturally posing an interesting challenge to the control community. Although there are widely accepted reduced order models to describe the dynamic behavior of microgrids, they are typically presented without details about the reduction procedure---hampering the understanding of the physical phenomena behind them. Preceded by an introduction to basic notions and definitions in power systems, the present survey reviews key characteristics and main components of a microgrid. We introduce the reader to the basic functionality of DC/AC inverters, as well as to standard operating modes and control schemes of inverter-interfaced power sources in microgrid applications. Based on this exposition and starting from fundamental physics, we present detailed dynamical models of the main microgrid components. Furthermore, we clearly state the underlying assumptions which lead to the standard reduced model with inverters represented by controllable voltage sources, as well as static network and load representations, hence, providing a complete modular model derivation of a three-phase inverter-based microgrid.

preprint2015arXiv

Modeling and Control of High-Voltage Direct-Current Transmission Systems: From Theory to Practice and Back

The problem of modeling and control of multi-terminal high-voltage direct-current transmission systems is addressed in this paper, which contains five main contributions. First, to propose a unified, physically motivated, modeling framework - based on port-Hamiltonian representations - of the various network topologies used in this application. Second, to prove that the system can be globally asymptotically stabilized with a decentralized PI control, that exploits its passivity properties. Close connections between the proposed PI and the popular Akagi's PQ instantaneous power method are also established. Third, to reveal the transient performance limitations of the proposed controller that, interestingly, is shown to be intrinsic to PI passivity-based control. Fourth, motivated by the latter, an outer-loop that overcomes the aforementioned limitations is proposed. The performance limitation of the PI, and its drastic improvement using outer-loop controls, are verified via simulations on a three-terminals benchmark example. A final contribution is a novel formulation of the power flow equations for the centralized references calculation.