Source author record

Daniela Pfeiffer

Daniela Pfeiffer appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2026arXiv

Neighbor2Inverse: Self-Supervised Denoising for Low-Dose Region-of-Interest Phase Contrast CT

Propagation-based X-ray phase-contrast imaging (PBI) enables high-contrast visualization of lung structures and holds strong medical potential. However, safe translation to the clinic will require a substantial radiation dose reduction, which inevitably increases image noise. Supervised convolutional-neural-network-based denoising can restore image quality but depends on paired low- and high-dose datasets, which are rarely available in practice. Self-supervised methods avoid this limitation, yet most are not well adapted to the inverse problem of PBI computed tomography (CT). We introduce Neighbor2Inverse, a self-supervised denoising framework designed for low-dose PBI-CT that generalizes to clinical CT. Building on the Neighbor2Neighbor principle, each noisy projection is subsampled into two variants that preserve structural information but contain independent noise realizations. These are reconstructed separately, and the resulting pairs are used to train a denoising network directly in the image domain. We benchmark the proposed method against established analytical and self-supervised denoising approaches. In region-of-interest PBI CT experiments, Neighbor2Inverse achieves superior noise suppression while preserving fine structural details, as demonstrated by improved contrast-to-noise ratio, spatial resolution, and composite image quality metrics. Competitive performance is also observed on clinical CT data under simulated low-dose conditions. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible. Code, data, and interactive figures are available at https://github.com/J-3TO/Neighbor2Inverse.