Source author record

D. T. Cameron

D. T. Cameron appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2015arXiv

The largest Swift AGN monitoring campaign: UV/optical variability in NGC 5548

We report on the largest Swift AGN monitoring program, concerning UV/optical variability in Seyferts. From 554 observations, over a 750d period, of the Seyfert galaxy NGC 5548, we see (McHardy et al. 2014) a good overall correlation between the X-ray and UV/optical bands,particularly on short timescales (tens of days). The UVOT bands are found to lag behind X-rays with a lag scaling as wavelength to the power 1.23 +/- 0.31, in excellent agreement with that expected (1.33) if UV/optical variability arises from reprocessing of X-rays by the accretion disc. However, the observed lags are ~3 times longer than expected from a standard Shakura-Sunyaev disc, raising real concerns about the detailed validity of this model. The results can be explained with a slightly larger mass and accretion rate, and a hotter disc, or if the disc is clumpy, thereby enhancing the emission from the outer regions.

preprint2014arXiv

Swift monitoring of NGC 5548: X-ray reprocessing and short term UV/optical variability

Lags measured from correlated X-ray/UV/optical monitoring of AGN allow us to determine whether UV/optical variability is driven by reprocessing of X-rays or X-ray variability is driven by UV/optical seed photon variations. We present the results of the largest study to date of the relationship between the X-ray, UV and optical variability in an AGN with 554 observations, over a 750d period, of the Seyfert 1 galaxy NGC 5548 with Swift. There is a good overall correlation between the X-ray and UV/optical bands, particularly on short timescales (tens of days). These bands lag the X-ray band with lags which are proportional to wavelength to the power 1.23+/-0.31. This power is very close to the power (4/3) expected if short timescale UV/optical variability is driven by reprocessing of X-rays by a surrounding accretion disc. The observed lags, however, are longer than expected from a standard Shakura-Sunyaev accretion disc with X-ray heating, given the currently accepted black hole mass and accretion rate values, but can be explained with a slightly larger mass and accretion rate, and a generally hotter disc. Some long term UV/optical variations are not paralleled exactly in the X-rays, suggesting an additional component to the UV/optical variability arising perhaps from accretion rate perturbations propagating inwards through the disc.

preprint2012arXiv

Correlated X-ray/Ultraviolet/Optical variability in the very low mass AGN NGC 4395

We report the results of a one year Swift X-ray/UV/optical programme monitoring the dwarf Seyfert nucleus in NGC 4395 in 2008-2009. The UV/optical flux from the nucleus was found to vary dramatically over the monitoring period, with a similar pattern of variation in each of the observed UV/optical bands (spanning 1900 - 5500 Å). In particular, the luminosity of NGC 4395 in the 1900 Å band changed by more than a factor of eight over the monitoring period. The fractional variability was smaller in the UV/optical bands than that seen in the X-rays, with the X-ray/optical ratio increasing with increasing flux. Pseudo-instantaneous flux measurements in the X-ray and each UV/optical band were well correlated, with cross correlation coefficients of >0.7, significant at 99.9 per cent confidence. Archival Swift observations from 2006 sample the intra-day X-ray/optical variability on NGC 4395. These archival data show a very strong correlation between the X-ray and b bands, with a cross-correlation coefficient of 0.84 (significant at >99 per cent confidence). The peak in the cross correlation function is marginally resolved and asymmetric, suggesting that X-rays lead the b band, but by 1 hour. In response to recent (August 2011) very high X-ray flux levels from NGC4395 we triggered Swift ToO observations, which sample the intra-hour X-ray/UV variability. These observations indicate, albeit with large uncertainties, a lag of the 1900 Å band behind the X-ray flux of ~400 s. The tight correlation between the X-ray and UV/optical lightcurves, together with the constraints we place on lag time-scale are consistent with the UV/optical variability of NGC 4395 being primarily due to reprocessing of X-ray photons by the accretion disc.