Source author record

D. Rosenthal

D. Rosenthal appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Radial excitations of heavy-light mesons from QCD sum rules

QCD sum rules are commonly used to predict the characteristics of ground-state hadrons. We demonstrate that two-point sum rules for the decay constants of charmed ($D^{(*)},D_s^{(*)}$) and bottom ($B^{(*)},B_s^{(*)}$) mesons can also be modified to estimate the decay constants of the first radial excitations, $D^{(*)'},D_s^{(*)'}$ and $B^{(*)'},B_s^{(*)'}$, respectively, provided the masses of these resonances are used as an input. For the radially excited charmed mesons we use available experimental data, whereas the masses of analogous bottom mesons are estimated from the heavy-quark limit. The decay constants predicted for the radial excitations of heavy-light pseudoscalar and vector mesons are systematically smaller than those of the ground states and we comment on the possible origin of this difference. Our results can be used in the sum rule calculations of heavy-to-light form factors and in the factorization approximations for nonleptonic $B$-meson decays where the decay constants of charmed mesons enter as input parameters.

preprint2000arXiv

16 x 25 Ge:Ga Detector Arrays for FIFI LS

We are developing two-dimensional 16 x 25 pixel detector arrays of both unstressed and stressed Ge:Ga photoconductive detectors for far-infrared astronomy from SOFIA. The arrays, based on earlier 5 x 5 detector arrays used on the KAO, will be for our new instrument, the Far Infrared Field Imaging Line Spectrometer (FIFI LS). The unstressed Ge:Ga detector array will cover the wavelength range from 40 to 120 microns, and the stressed Ge:Ga detector array from 120 to 210 microns. The detector arrays will be operated with multiplexed integrating amplifiers with cryogenic readout electronics located close to the detector arrays. The design of the stressed detector array and results of current measurements on several prototype 16 pixel linear arrays are reported. They demonstrate the feasibility of the current concept. ***This paper does not include Figures due to astro-ph size limitations. Please download entire file at http://fifi-ls.mpe-garching.mpg.de/spie.det.ps.gz ***

preprint2000arXiv

Realizing 3D Spectral Imaging in the Far-Infrared: FIFI LS

We present a progress report on the design and construction of the Field-Imaging Far-Infrared Line Spectrometer (FIFI LS) for the SOFIA airborne observatory. The design of the instrument is driven by the goal of maximizing observing efficiency, especially for observations of faint, extragalactic objects. Thus, FIFI LS utilizes an integral field technique that uses slicer mirrors to optically re-arrange the two-dimensional field into a single slit for a long slit spectrometer. Effectively, a 5x5 pixel spatial field of view is imaged to a 25x1 pixel slit and dispersed to a 25x16 pixel, two-dimensional detector array, providing diffraction-limited spatial and spectral multiplexing. In this manner, the instrument employs two parallel, medium resolution (R~2000) grating spectrometers for simultaneous observations in two bands: a short wavelength band (42 to 110 micron) and a long wavelength band (110 to 210 micron). Overall, for each of the 25 spatial pixels, the instrument can cover a velocity range of ~1500 km/s around selected far-infrared lines with an estimated sensitivity of 2x10^-15 W Hz^1/2 per pixel. This arrangement provides good spectral coverage with high responsivity. ***This paper does not include Figures due to astro-ph size limitations. Please download entire file at http://fifi-ls.mpe-garching.mpg.de/fifils.ps.gz ****