Source author record

D. Campo

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

6works
5topics
4close collaborators

Published work

6 publications

preprint2015arXiv

IsoDAR@KamLAND: A Conceptual Design Report for the Technical Facility

This conceptual design report describes the technical facility for the IsoDAR electron-antineutrino source at KamLAND. The IsoDAR source will allow an impressive program of neutrino oscillation and electroweak physics to be performed at KamLAND. This report provides information on the physics case, the conceptual design for the subsystems, alternative designs considered, specifics of installation at KamLAND, and identified needs for future development. We discuss the risks we have identified and our approach to mitigating those risks with this design. A substantial portion of the conceptual design is based on three years of experimental efforts and on industry experience. This report also includes information on the conventional facilities.

preprint2013arXiv

Whitepaper on the DAEdALUS Program

This whitepaper describes the status of the DAEdALUS program for development of high power cyclotrons as of the time of the final meeting of the Division of Particles and Fields 2013 Community Study ("Snowmass"). We report several new results, including a measurement capability between 4 and 12 degrees on the CP violating parameter in the neutrino sector. Past results, including the capability of the IsoDAR high Dm^2 antielectron neutrino disappearance search, are reviewed. A discussion of the R&D successes, including construction of a beamline teststand, and future plans are provided. This text incorporates short whitepapers written for subgroups in the Intensity Frontier and Frontier Capabilities Working Groups that are available on the Snowmass website.

preprint2012arXiv

Cost-effective Design Options for IsoDAR

This whitepaper reviews design options for the IsoDAR electron antineutrino source. IsoDAR is designed to produce 2.6×10222.6 \times 10^{22} electron antineutrinos per year with an average energy of 6.4 MeV, using isotope decay-at-rest. Aspects which must be balanced for cost-effectiveness include: overall cost; rate and energy distribution of the electron antineutrino flux and backgrounds; low technical risk; compactness; simplicity of underground construction and operation; reliability; value to future neutrino physics programs; and value to industry. We show that the baseline design outlined here is the most cost effective.

preprint2012arXiv

Multimegawatt DAEδδALUS Cyclotrons for Neutrino Physics

DAEδδALUS (Decay-At-rest Experiment for δCPδ_{CP} studies At the Laboratory for Underground Science) provides a new approach to the search for CP violation in the neutrino sector. High-power continuous-wave proton cyclotrons efficiently provide the necessary proton beams with an energy of up to 800 MeV to create neutrinos from pion and muon decay-at-rest. The experiment searches for νˉμ→νˉe\barν_μ \rightarrow \barν_e at short baselines corresponding to the atmospheric Δm2Δm^2 region. The νˉe\barν_e will be detected via inverse beta decay. Thus, the cyclotrons will be employed at a future ultra-large gadolinium-doped water or scintillator detector. In this paper we address the most challenging questions regarding a cyclotron-based high-power proton driver in the megawatt range with a kinetic energy of 800 MeV. Aspects of important subsystems like the ion source and injection chain, the magnet design and radio frequency system will be addressed. Precise beam dynamics simulations, including space charge and the H2+\text{H}_2^+ stripping process, are the base for the characterization and quantification of the beam halo -- one of the most limiting processes in high-power particle accelerators.

preprint2012arXiv

Proposal for an Electron Antineutrino Disappearance Search Using High-Rate 8Li Production and Decay

This paper introduces a novel, high-intensity source of electron antineutrinos from the production and subsequent decay of 8Li. When paired with an existing ~1 kton scintillator-based detector, this <E_ν>=6.4 MeV source opens a wide range of possible searches for beyond standard model physics via studies of the inverse beta decay interaction. In particular, the experimental design described here has unprecedented sensitivity to electron antineutrino disappearance at Δm2∼Δm^2\sim 1 eV2^2 and features the ability to distinguish between the existence of zero, one, and two sterile neutrinos.

preprint2010arXiv

Cyclinac Medical Accelerators Using Pulsed C6+/H2+ Ion Sources

Charged particle therapy, or so-called hadrontherapy, is developing very rapidly. There is large pressure on the scientific community to deliver dedicated accelerators, providing the best possible treatment modalities at the lowest cost. In this context, the Italian research Foundation TERA is developing fast-cycling accelerators, dubbed 'cyclinacs'. These are a combination of a cyclotron (accelerating ions to a fixed initial energy) followed by a high gradient linac boosting the ions energy up to the maximum needed for medical therapy. The linac is powered by many independently controlled klystrons to vary the beam energy from one pulse to the next. This accelerator is best suited to treat moving organs with a 4D multi-painting spot scanning technique. A dual proton/carbon ion cyclinac is here presented. It consists of an Electron Beam Ion Source, a superconducting isochronous cyclotron and a high-gradient linac. All these machines are pulsed at high repetition rate (100-400 Hz). The source should deliver both C6+ and H2+ ions in short pulses (1.5 μs flat-top) and with sufficient intensity (at least 108 fully stripped carbon ions at 300 Hz). The cyclotron accelerates the ions to 120 MeV/u. It features a compact design (with superconducting coils) and a low power consumption. The linac has a novel C-band high gradient structure and accelerates the ions to variable energies up to 400 MeV/u. High RF frequencies lead to power consumptions which are much lower than the ones of synchrotrons for the same ion extraction energy. This work is part of a collaboration with the CLIC group, which is working at CERN on high-gradient electron-positron colliders.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.