Source author record

Colby Jurgenson

Colby Jurgenson appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2016arXiv

Design and Construction of VUES: the Vilnius University Echelle Spectrograph

In February of 2014 the Yale Exoplanet Laboratory was commissioned to design, build, and deliver a high resolution (R = 60,000) spectrograph for the 1.65-meter telescope at the Moletai Astronomical Observatory. The observatory is operated by the Institute of Theoretical Physics and Astronomy at Vilnius University. The Vilnius University Echelle Spectrograph (VUES) is a white-pupil design that is fed via an octagonal fiber from the telescope and has an operational bandpass from 400 to 880 nm. VUES incorporates a novel modular optomechanical design that allows for quick assembly and alignment on commercial optical tables. This approach allowed the spectrograph to be assembled and commissioned at Yale using lab optical tables and then reassembled at the observatory on a different optical table with excellent repeatability. The assembly and alignment process for the spectrograph was reduced to a few days, allowing the spectrograph to be completely disassembled for shipment to Lithuania, and then installed at the observatory during a 10-day period in June of 2015.

preprint2015arXiv

Fiber scrambling for high-resolution spectrographs. II. A double fiber scrambler for Keck Observatory

We have designed a fiber scrambler as a prototype for the Keck HIRES spectrograph, using double scrambling to stabilize illumination of the spectrometer and a pupil slicer to increase spectral resolution to R = 70,000 with minimal slit losses. We find that the spectral line spread function (SLSF) for the double scrambler observations is 18 times more stable than the SLSF for comparable slit observations and 9 times more stable than the SLSF for a single fiber scrambler that we tested in 2010. For the double scrambler test data, we further reduced the radial velocity scatter from an average of 2.1 m/s to 1.5 m/s after adopting a median description of the stabilized SLSF in our Doppler model. This demonstrates that inaccuracies in modeling the SLSF contribute to the velocity RMS. Imperfect knowledge of the SLSF, rather than stellar jitter, sets the precision floor for chromospherically quiet stars analyzed with the iodine technique using Keck HIRES and other slit-fed spectrometers. It is increasingly common practice for astronomers to scale stellar noise in quadrature with formal errors such that their Keplerian model yields a chi-squared fit of 1.0. When this is done, errors from inaccurate modeling of the SLSF (and perhaps from other sources) are attributed to the star and the floor of the stellar noise is overestimated.