Source author record

Chul Seung Kay

Chul Seung Kay appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2015arXiv

Evaluation of Elekta SymmetryTM 4D IGRT system by using moving lung phantom

Purpose: 4D CBCT is a beneficial tool for the treatment of movable tumors, because it can help us to understand where the tumors are actually located and have a precise treatment plan. However, there is a limitation that general CBCT images cannot perfectly help the sophisticated registration. On the other hand, SymmetryTM 4D IGRT system of Elekta can offer the 4D CBCT registration option. In this study, we intend to evaluate the usefulness of SymmetryTM. Method and Materials: Planning CT images of the CIRS moving lung phantom were acquired from 4D MDCT. And they are sorted as 10 phases from 0% phase to 90% phase. The thickness of CT images was 1 mm. Acquired MDCT images were transferred to the contouring software and a virtual target was generated. An one arc VMAT plan was performed by using the treatment planning system on the virtual target. Finally, the movement of the phantom was verified through XVI SymmetryTM system. Results: The physical movement of CIRS moving lung phantom was +/- 10.0 mm in superior-inferior direction, +/- 1.0 mm in lateral direction, and +/- 2.5 mm in anterior-posterior direction. The movement of the phantom was measured from 4D MDCT registration as +/- 10.2 mm in superior-inferior direction, +/- 0.9 mm in lateral direction, and +/- 2.45 mm in anterior-posterior direction. The movement of the phantom was measured from SymmetryTM registration as +/- 10.1 mm in superior-inferior direction, +/- 0.9 mm in lateral direction, and +/- 2.4 mm in anterior/posterior direction. Conclusion: It is confirmed that 4D CBCT is a beneficial tool for the treatment of movable tumors. Therefore, 4D registration of SymmetryTM can increase the precision of the registration when a movable tumor is a target of radiation treatment.