Source author record

Christopher C. Govern

Christopher C. Govern appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
1close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

How biochemical resources determine fundamental limits in cellular sensing

Living cells deploy many resources to sense their environments, including receptors, downstream signaling molecules, time and fuel. However, it is not known which resources fundamentally limit the precision of sensing, like weak links in a chain, and which can compensate each other, leading to trade-offs between them. We show by modeling that in equilibrium systems the precision is limited by the number of receptors; the downstream network can never increase precision. This limit arises from a trade-off between the removal of extrinsic noise in the receptor and intrinsic noise in the downstream network. Non-equilibrium systems can lift this trade-off by storing the receptor state over time in chemical modification states of downstream molecules. As we quantify for a push-pull network, this requires i) time and receptors; ii) downstream molecules; iii) energy (fuel turnover) to drive modification. These three resource classes cannot compensate each other, and it is the limiting class which sets the fundamental sensing limit. Within each class, trade-offs are possible. Energy allows a power-speed trade-off, while time can be traded against receptors.

preprint2012arXiv

Fundamental Limits on Sensing Chemical Concentrations with Linear Biochemical Networks

Living cells often need to extract information from biochemical signals that are noisy. We study how accurately cells can measure chemical concentrations with signaling networks that are linear. For stationary signals of long duration, they can reach, but not beat, the Berg-Purcell limit, which relies on uniformly averaging in time the fluctuations in the input signal. For short times or nonstationary signals, however, they can beat the Berg-Purcell limit, by non-uniformly time-averaging the input. We derive the optimal weighting function for time averaging and use it to provide the fundamental limit of measuring chemical concentrations with linear signaling networks.