Source author record

Christian M Langton

Christian M Langton appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2011arXiv

A CAD Interface for GEANT4

Typically used as a tool for Monte Carlo simulation of high energy physics experiments, GEANT4 is increasingly being employed for the simulation of complex radiotherapy treatments. Often the specification of components within a clinical linear accelerator treatment head is provided in a CAD file format. Direct import of these CAD files into GEANT4 may not be possible, and complex components such as individual leaves within a multi-leaf collimator may be difficult to define via other means. Solutions that allow for users to work around the limited support in the GEANT4 toolkit for loading predefined CAD geometries has been presented by others, however these solutions require intermediate file format conversion using commercial software. Here within we describe a technique that allows for CAD models to be directly loaded as geometry without the need for commercial software and intermediate file format conversion. Robustness of the interface was tested using a set of CAD models of various complexity; for the models used in testing, no import errors were reported and all geometry was found to be navigable by GEANT4.

preprint2011arXiv

Technical Note: Radiotherapy dose calculations using GEANT4 and the Amazon Elastic Compute Cloud

Cloud computing allows for vast computational resources to be leveraged quickly and easily in bursts as and when required. Using the Amazon Elastic Compute Cloud and the Amazon Simple Storage Solution, we describe a technique that allows for Monte Carlo radiotherapy dose calculations to be performed using GEANT4 and executed in the cloud. Simulation cost and completion time was evaluated as a function of instance count using compute instances acquired via biding on the Elastic Compute Cloud spot market. Bidding for instances on the instance spot market was found to be 35-60% of the cost of on-demand instances of the same type. Using the technique, we demonstrate the potential usefulness of cloud computing as a solution for rapid Monte Carlo simulation for radiotherapy dose calculation.