Researcher profile

Chetan Mishra

Chetan Mishra contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Identifying Oscillations Injected by Inverter-Based Solar Energy Sources

Inverter-based solar energy sources are becoming widely integrated into modern power systems. However, their impacts on the system in the frequency domain are rarely investigated at a higher frequency range than conventional electromechanical oscillations. This paper presents evidence of the emergence of an oscillation mode injected by inverter-based solar energy sources in Dominion Energy's service territory. This new mode was recognized from the analysis of real-world ambient synchrophasor and point-of-wave data. The analysis was performed by developing customized synchrophasor analysis tools deployed on the PredictiveGrid^{TM} platform implemented at Dominion Energy. Herein, we describe and illustrate the preliminary analysis results acquired from spectrogram observations, power spectral density plots, and mode shape estimation. The emergence and propagation of this new mode in Dominion Energy's footprint is illustrated using a heatmap based on a proposed frequency component energy metric, which helps to assess this oscillation's spread and impact.

preprint2020arXiv

A Fixed-Flexible BESS Allocation Scheme for Transmission Networks Considering Uncertainties

Battery energy storage systems (BESSs) can play a key role in mitigating the intermittency and uncertainty associated with adding large amounts of renewable energy to the bulk power system (BPS). Two BESS technologies that have gained prominence in this regard are Lithium-ion (LI) BESS and Vanadium redox flow (VRF) BESS. This paper proposes a fixed-flexible BESS allocation scheme that exploits the complementary characteristics of LI and VRF BESSs to attain optimal techno-economic benefits in a wind-integrated BPS. Studies carried out on relatively large transmission networks demonstrate that benefits such as reduction in system operation cost, wind spillage, voltage fluctuations, and discounted payback period, can be realized by using the proposed scheme.

preprint2020arXiv

Adaptive LVRT Settings Adjustment for Enhancing Voltage Security of Renewable-Rich Electric Grids

Inverter based renewable generation (RG), especially at the distribution level, is supposed to trip offline during an islanding situation. However, islanding detection is done by comparing the voltage and frequency measurements at the point of common coupling (PCC), with limits defined in the form of ride-through curves. Current practice is to use the same limit throughout the year independent of the operating conditions. This could result in the tripping of RG at times when the system is already weak, thereby posing a threat to voltage security by heavily limiting the load margin (LM). Conversely, heavily relaxing these limits would result in scenarios where the generation does not go offline even during an islanding situation. The proposed methodology focuses on optimizing low-voltage ride-through (LVRT) settings at selective RGs as a preventive control for maintaining a desired steady-state voltage stability margin while not sacrificing dependability during islanding. The proposed process is a multi-stage approach, in which at each stage, a subset of estimated poor-quality solutions is screened out based on various sensitivities. A full continuation power flow (CPFLOW) is only run at the beginning and in the last stage on a handful of remaining candidate solutions, thereby cutting down heavily on the computation time. The effectiveness of the approach is demonstrated on the IEEE 9-bus system.

preprint2020arXiv

Critical Clearing Time Sensitivity for Differential-Algebraic Power System Model

Standard power systems are modeled using differential-algebraic equations (DAE). Following a transient event, voltage collapse can occur as a bifurcation of the transient load flow solutions which is marked by the system trajectory reaching a singular surface in state space where the voltage causality is lost. If the system is under such a risk, preventive control decisions such as changes in AVR setpoints need to be taken to enhance the stability. In this regard, the knowledge of sensitivity of critical clearing time (CCT) to controllable system parameters can be of great help. The stability boundary of DAE systems is more complicated than ODE systems where in addition to stable manifolds of unstable equilibrium points (UEP) and periodic orbits, singular surfaces play an important role. In the present work, we derive the expressions for CCT sensitivity for a generic DAE model using trajectory sensitivities with applications to power system transient stability analysis (TSA) and preventive control. The results are illustrated for multiple test systems which are then validated against computationally intensive time-domain simulations (TDS).

preprint2020arXiv

Low Voltage Ride Through (LVRT) Constrained Transient Stability Assessment Using Lyapunov Functions Family Method

Growing penetration of renewable generation in power systems brings more challenges in transient stability assessment using direct methods. One of the reasons is the inability to assess the risk of instability brought by tripping of a large amount of RGs due to violation of their ride through curves. In this paper, a scalable approach is proposed based on the Lyapunov functions family to estimate the stability region under ride through constraints. An inner polytopic approximation to the feasibility region is proposed to convexify the overall problem. The acquired constrained stability region estimate helps capture trajectories that trigger undesirable tripping of renewable generation. A 2-machine system is used to visualize its effectiveness.

preprint2020arXiv

Towards Critical Clearing Time Sensitivity for DAE Systems with Singularity

Standard power system models are parameter dependent differential-algebraic equation (DAE) type. Following a transient event, voltage collapse can occur as a bifurcation of the transient load flow solutions which is marked by the system trajectory reaching a singular surface in state space where the voltage causality is lost. If a fault is expected to cause voltage collapse, preventive control decisions such as changes in AVR settings need to be taken in order to get enhance the system stability. In this regard, the knowledge of sensitivity of critical clearing time (CCT) to controllable system parameters can be of great help. The quasi-stability boundary of DAE systems is more complicated than ODE systems where in addition to unstable equilibrium points (UEP) and periodic orbits, singularity plays an important role making the problem challenging. The stability boundary is then made up of a number of dynamically distinct components. In the present work, we derive the expression for CCT sensitivity for the phenomenon where the critical fault-on trajectory intersects the singular surface itself which is one such component forming the stability boundary. The results are illustrated for a small test system in order to gain visual insights.

preprint2019arXiv

Critical Clearing Time Sensitivity for Inequality Constrained Systems

From a stability perspective, a renewable generation (RG)-rich power system is a constrained system. As the quasistability boundary of a constrained system is structurally very different from that of an unconstrained system, finding the sensitivity of critical clearing time (CCT) to change in system parameters is very beneficial for a constrained power system, especially for planning/revising constraints arising from system protection settings. In this paper, we derive the first order sensitivity of a constrained power system using trajectory sensitivities of fault-on and post-fault trajectories. The results for the test system demonstrate the dependence between ability to meet angle and frequency constraints, and change in power system parameters such as operating conditions and inertia.