Source author record

Charles-A. Cuenod

Charles-A. Cuenod appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

1works
1topics
3close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2015arXiv

Laplace deconvolution on the basis of time domain data and its application to Dynamic Contrast Enhanced imaging

In the present paper we consider the problem of Laplace deconvolution with noisy discrete non-equally spaced observations on a finite time interval. We propose a new method for Laplace deconvolution which is based on expansions of the convolution kernel, the unknown function and the observed signal over Laguerre functions basis (which acts as a surrogate eigenfunction basis of the Laplace convolution operator) using regression setting. The expansion results in a small system of linear equations with the matrix of the system being triangular and Toeplitz. Due to this triangular structure, there is a common number $m$ of terms in the function expansions to control, which is realized via complexity penalty. The advantage of this methodology is that it leads to very fast computations, produces no boundary effects due to extension at zero and cut-off at $T$ and provides an estimator with the risk within a logarithmic factor of the oracle risk. We emphasize that, in the present paper, we consider the true observational model with possibly nonequispaced observations which are available on a finite interval of length $T$ which appears in many different contexts, and account for the bias associated with this model (which is not present when $T\rightarrow\infty$). The study is motivated by perfusion imaging using a short injection of contrast agent, a procedure which is applied for medical assessment of micro-circulation within tissues such as cancerous tumors. Presence of a tuning parameter $a$ allows to choose the most advantageous time units, so that both the kernel and the unknown right hand side of the equation are well represented for the deconvolution. The methodology is illustrated by an extensive simulation study and a real data example which confirms that the proposed technique is fast, efficient, accurate, usable from a practical point of view and very competitive.