Researcher profile

Chang-Hoon Lee

Chang-Hoon Lee contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Astrometrically Registered Simultaneous Observations of the 22 GHz H$_2$O and the 43GHz SiO masers towards R Leonis Minoris using KVN and Source/Frequency Phase Referencing

Oxygen-rich Asymptotic Giant Branch (AGB) stars can be intense emitters of SiO ($v$=1 and 2, J=1$\rightarrow$0) and H$_2$O maser lines at 43 and 22 GHz, respectively. VLBI observations of the maser emission provide a unique tool to probe the innermost layers of the circumstellar envelopes in AGB stars. Nevertheless, the difficulties in achieving astrometrically aligned \water\ and $v$=1 and $v$=2 SiO maser maps have traditionally limited the physical constraints that can be placed on the SiO maser pumping mechanism. We present phase referenced simultaneous spectral-line VLBI images for the SiO $v$=1 and $v$=2, J=1$\rightarrow$0, and H$_2$O maser emission around the AGB star R\,LMi, obtained from the Korean VLBI Network (KVN). The simultaneous multi-channel receivers of the KVN offer great possibilities for astrometry in the frequency domain. With this facility we have produced images with bona-fide absolute astrometric registration between high frequency maser transitions of different species to provide the positions of the \water\ maser emission, and the centre of the SiO maser emission, and hence reducing the uncertainty in the proper motion for R\,LMi by an order of magnitude over that from Hipparcos. This is the first successful demonstration of source frequency phase referencing for mm-VLBI spectral-line observations and also where the ratio between the frequencies is not an integer.

preprint2014arXiv

Verification of the Astrometric Performance of the Korean VLBI Network, using comparative SFPR studies with the VLBA at 14/7 mm

The Korean VLBI Network (KVN) is a new mm-VLBI dedicated array with capability for simultaneous observations at multiple frequencies, up to 129 GHz. The innovative multi-channel receivers present significant benefits for astrometric measurements in the frequency domain. The aim of this work is to verify the astrometric performance of the KVN using a comparative study with the VLBA, a well established instrument. For that purpose, we carried out nearly contemporaneous observations with the KVN and the VLBA, at 14/7 mm, in April 2013. The KVN observations consisted of simultaneous dual frequency observations, while the VLBA used fast frequency switching observations. We used the Source Frequency Phase Referencing technique for the observational and analysis strategy. We find that having simultaneous observations results in a superior performance for compensation of all atmospheric terms in the observables, in addition to offering other significant benefits for astrometric analysis. We have compared the KVN astrometry measurements to those from the VLBA. We find that the structure blending effects introduce dominant systematic astrometric shifts and these need to be taken into account. We have tested multiple analytical routes to characterize the impact of the low resolution effects for extended sources in the astrometric measurements. The results from the analysis of KVN and full VLBA datasets agree within 2-$σ$ of the thermal error estimate. We interpret the discrepancy as arising from the different resolutions. We find that the KVN provides astrometric results with excellent agreement, within 1-$σ$, when compared to a VLBA configuration which has a similar resolution. Therefore this comparative study verifies the astrometric performance of KVN using SFPR at 14/7 mm, and validates the KVN as an astrometric instrument.