Source author record

Chai Pei

Chai Pei appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

Attenuation correction with Region Growing Method used in the Positron Emission Mammography System

Positron Emission Mammography imaging system (PEMi) is a nuclear medicine diagnosis method dedicated for breast imaging. It provides a better resolution in detection of millimeter-sized breast tumors than whole-body PET. To address the requirement of semi-quantitative analysis with the radiotracer concentration map of the breast, a new attenuation correction method based on three-dimensional seeded region growing image segmentation (3DSRG-AC) solution was developed. The method gives a 3D connected region as the segmentation result instead of image slices. The continuously segmentation property makes this new method free of activity variation of breast tissues. Threshold value chosen is the key point for the segmentation process. The first valley of the grey level histogram of the reconstruction image is set as the lower threshold, which works fine in clinical application. Results show that attenuation correction for PEMi improves the image quality and the quantitative accuracy of radioactivity distribution determination. Attenuation correction also improves the probabilities to detect small and early breast tumors.

preprint2014arXiv

PET image reconstruction with system matrix containing point spread function derived from single photon incidence response

In positron emission tomography (PET) imaging, statistical iterative reconstruction (IR) techniques appear particularly promising since they can provide accurate system model. The system model matrix which describes the relationship between image space and projection space is important to the image quality. It contains some factors such as geometrical component and blurring component. The blurring component is usually described by point spread function (PSF). A PSF matrix derived from the single photon incidence response function is studied. And then an IR method based on the system matrix containing the PSF is developed. More specifically, the gamma photon incidence on a crystal array is simulated by Monte Carlo (MC) simulation, and then the single photon incidence response functions are calculated. Subsequently, the single photon incidence response functions is used to compute the coincidence blurring factor according to the physical process of PET coincidence detection. Through weighting the ordinary system matrix response by the coincidence blurring factors, the IR system matrix containing PSF is finally established. Using this system matrix, the image is reconstructed by ordered subset expectation maximization (OSEM) algorithm. The experimental results show that the proposed system matrix can obviously improve the image radial resolution, contrast and noise property. Furthermore, the simulated single gamma-ray incidence response function only depends on the crystal configuration, so the method could be extended to any PET scanners with the same detector crystal configuration.