Source author record

Carlos Sierra

Carlos Sierra appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

The Integration and Testing Program for the Simons Observatory Large Aperture Telescope Optics Tubes

The Simons Observatory (SO) will be a cosmic microwave background (CMB) survey experiment with three small-aperture telescopes and one large-aperture telescope, which will observe from the Atacama Desert in Chile. In total, SO will field over 60,000 transition-edge sensor (TES) bolometers in six spectral bands centered between 27 and 280 GHz in order to achieve the sensitivity necessary to measure or constrain numerous cosmological quantities, as outlined in The Simons Observatory Collaboration et al. (2019). The 6~m Large Aperture Telescope (LAT), which will target the smaller angular scales of the CMB, utilizes a cryogenic receiver (LATR) designed to house up to 13 individual optics tubes. Each optics tube is comprised of three silicon lenses, IR blocking filters, and three dual-polarization, dichroic TES detector wafers. The scientific objectives of the SO project require these optics tubes to achieve high-throughput optical performance while maintaining exquisite control of systematic effects. We describe the integration and testing program for the SO LATR optics tubes that will verify the design and assembly of the optics tubes before they are shipped to the SO site and installed in the LATR cryostat. The program includes a quick turn-around test cryostat that is used to cool single optics tubes and validate the cryogenic performance and detector readout assembly. We discuss the optical design specifications the optics tubes must meet to be deployed on sky and the suite of optical test equipment that is prepared to measure these requirements.

preprint2020arXiv

Small Aperture Telescopes for the Simons Observatory

The Simons Observatory (SO) is an upcoming cosmic microwave background (CMB) experiment located on Cerro Toco, Chile, that will map the microwave sky in temperature and polarization in six frequency bands spanning 27 to 285 GHz. SO will consist of one 6-meter Large Aperture Telescope (LAT) fielding $\sim$30,000 detectors and an array of three 0.42-meter Small Aperture Telescopes (SATs) fielding an additional 30,000 detectors. This synergy will allow for the extremely sensitive characterization of the CMB over angular scales ranging from an arcmin to tens of degrees, enabling a wide range of scientific output. Here we focus on the SATs targeting degree angular scales with successive dichroic instruments observing at Mid-Frequency (MF: 93/145 GHz), Ultra-High-Frequency (UHF: 225/285 GHz), and Low-Frequency (LF: 27/39 GHz). The three SATs will be able to map $\sim$10% of the sky to a noise level of 2 $μ$K-arcmin when combining 93 and 145 GHz. The multiple frequency bands will allow the CMB to be separated from galactic foregrounds (primarily synchrotron and dust), with the primary science goal of characterizing the primordial tensor-to-scalar ratio, $r$, at a target level of $σ\left(r\right) \approx 0.003$.

preprint2019arXiv

The Design of The CCAT-prime Epoch of Reionization Spectrometer Instrument

The Epoch of Reionization Spectrometer (EoR-Spec) is an instrument module for the Prime-Cam receiver of the 6 m aperture CCAT-prime Telescope at 5600 m in Chile. EoR-Spec will perform 158 $μ$m [CII] line intensity mapping of star-forming regions at redshifts between 3.5 and 8 (420 - 210 GHz), tracing the evolution of structure during early galaxy formation. At lower redshifts, EoR-Spec will observe galaxies near the period of peak star formation - when most stars in today's universe were formed. At higher redshifts, EoR-Spec will trace the late stages of reionization, the early stages of galaxy assembly, and the formation of large-scale, three-dimensional clustering of star-forming galaxies. To achieve its science goals, EoR-Spec will utilize CCAT-prime's exceptionally low water vapor site, large field of view ($\sim 5$ degrees at 210 GHz), and narrow beam widths ($\sim 1$ arcminute at 210 GHz). EoR-Spec will be outfitted with a cryogenic, metamaterial, silicon substrate-based Fabry-Perot Interferometer operating at a resolving power ($λ/Δλ$) of 100. Monolithic dichroic arrays of cryogenic, feedhorn-coupled transition edge sensor bolometers provide approximately 6000 detectors, which are read out using a frequency division multiplexing system based on microwave SQUIDs. The novel design allows the measurement of the [CII] line at two redshifts simultaneously using dichroic pixels and two orders of the Fabry-Perot. Here we present the design and science goals of EoR-Spec, with emphasis on the spectrometer, detector array, and readout designs.

preprint2013arXiv

Nanoscale capacitance: a classical charge-dipole approximation

Modeling nanoscale capacitance presents particular challenge because of dynamic contribution from electrodes, which can usually be neglected in modeling macroscopic capacitance and nanoscale conductance. We present a model to calculate capacitances of nano-gap configurations and define effective capacitances of nanoscale structures. The model is implemented by using a classical atomic charge-dipole approximation and applied to calculate capacitance of a carbon nanotube nano-gap and effective capacitance of a buckyball inside the nano-gap. Our results show that capacitance of the carbon nanotube nano-gap increases with length of electrodes which demonstrates the important roles played by the electrodes in dynamic properties of nanoscale circuits.