Source author record

C. Perry

C. Perry appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

A high-resolution, low-latency, bunch-by-bunch feedback system for nano-beam stabilization

We report the design, operation and performance of a high-resolution, low-latency, bunch-by-bunch feedback system for nano-beam stabilisation. The system employs novel, ultra-low quality-factor cavity beam position monitors (BPMs), a two-stage analogue signal down-mixing system, and a digital signal processing and feedback board incorporating an FPGA. The FPGA firmware allows for the real-time integration of up to fifteen samples of the BPM waveforms within a measured latency of 232 ns. We show that this real-time sample integration improves significantly the beam position resolution and, consequently, the feedback performance. The best demonstrated real-time beam position resolution was 19 nm, which, as far as we are aware, is the best real-time resolution achieved in any operating BPM system. The feedback was operated in two complementary modes to stabilise the vertical position of the ultra-small beam produced at the focal point of the ATF2 beamline at KEK. In single-BPM feedback mode, beam stabilisation to 50$\pm$5 nm was demonstrated. In two-BPM feedback mode, beam stabilisation to 41$\pm$4 nm was achieved.

preprint2020arXiv

A sub-micron resolution, bunch-by-bunch beam trajectory feedback system and its application to reducing wakefield effects in single-pass beamlines

A high-precision intra-bunch-train beam orbit feedback correction system has been developed and tested in the ATF2 beamline of the Accelerator Test Facility at the High Energy Accelerator Research Organization in Japan. The system uses the vertical position of the bunch measured at two beam position monitors (BPMs) to calculate a pair of kicks which are applied to the next bunch using two upstream kickers, thereby correcting both the vertical position and trajectory angle. Using trains of two electron bunches separated in time by 187.6~ns, the system was optimised so as to stabilize the beam offset at the feedback BPMs to better than 350~nm, yielding a local trajectory angle correction to within 250~nrad. The quality of the correction was verified using three downstream witness BPMs and the results were found to be in agreement with the predictions of a linear lattice model used to propagate the beam trajectory from the feedback region. This same model predicts a corrected beam jitter of c.~1~nm at the focal point of the accelerator. Measurements with a beam size monitor at this location demonstrate that reducing the trajectory jitter of the beam by a factor of 4 also reduces the increase in the measured beam size as a function of beam charge by a factor of c.~1.6.

preprint2020arXiv

Attosecond Dynamics in Liquids

Attosecond science is well developed for atoms and promising results have been obtained for molecules and solids. Here, we review the first steps in developing attosecond time-resolved measurements in liquids. These advances provide access to time-domain studies of electronic dynamics in the natural environment of chemical reactions and biological processes. We concentrate on two techniques that are representative of the two main branches of attosecond science: pump-probe measurements using attosecond pulses and high-harmonic spectroscopy (HHS). In the first part, we discuss attosecond photoelectron spectroscopy with cylindrical microjets and its application to measure time delays between liquid and gaseous water. We present the experimental techniques, the new data-analysis methods and the experimental results. We describe in detail the conceptual and theoretical framework required to fully describe attosecond chronoscopy in liquids at a quantum-mechanical level. This includes photoionization delays, scattering delays, as well as a coherent description of electron transport and (laser-assisted) photoemission and scattering. As a consequence, we show that attosecond chronoscopy of liquids is, in general, sensitive to both types of delays, as well as the electron mean-free paths. Through detailed modeling, involving state-of-the-art quantum scattering and Monte-Carlo trajectory methods, we show that the photoionization delays dominate in attosecond chronoscopy of liquid water at photon energies of 20-30 eV. This conclusion is supported by a near-quantitative agreement between experiment and theory. In the second part, we introduce HHS of liquids based on flat microjets. These results represent the first observation of high-harmonic generation (HHG) in liquids extending well beyond the visible into the extreme-ultraviolet regime.

preprint2012arXiv

Present status and first results of the final focus beam line at the KEK Accelerator Test Facility

ATF2 is a final-focus test beam line which aims to focus the low emittance beam from the ATF damping ring to a vertical size of about 37 nm and to demonstrate nanometer level beam stability. Several advanced beam diagnostics and feedback tools are used. In December 2008, construction and installation were completed and beam commissioning started, supported by an international team of Asian, European, and U.S. scientists. The present status and first results are described.