Researcher profile

C. Groeneveld

C. Groeneveld contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

Pushing subarcsecond resolution imaging down to 30 MHz with the trans-European International LOFAR Telescope

Relatively little information is available about the Universe at ultra-low radio frequencies, i.e. below 50 MHz (ULF), although the ULF spectral window contains a wealth of unique diagnostics for studying galactic and extragalactic phenomena. Sub-arcsecond resolution imaging at these frequencies is extremely difficult, due to the long baselines (>1000 km) required and large ionospheric perturbations. We have conducted a pilot project to investigate the ULF performance and potential of the International LOFAR Telescope (ILT), a trans-European interferometric array with baselines up to ~2000 km and observing frequencies down to 10 MHz. We have successfully produced images with sub-arcsecond resolution for 6 radio sources at frequencies down to 30 MHz. This is more than an order of magnitude better resolution than pre-ILT observations at similar frequencies. The six targets that we have imaged (3C 196, 3C 225, 3C 273, 3C 295, 3C 298 and 3C 380) are bright radio sources with compact structures. By comparing our data of 3C 196 and 3C 273 with observations at higher frequencies, we investigate their spatially resolved radio spectral properties. Our success shows that at frequencies down to 30 MHz, sub-arcsecond imaging with the ILT is possible. Further analysis is needed to determine the feasibility of observations of fainter sources or sources with less compact emission.

preprint2021arXiv

Sub-arcsecond imaging with the International LOFAR Telescope I. Foundational calibration strategy and pipeline

[abridged] The International LOFAR Telescope is an interferometer with stations spread across Europe. With baselines of up to ~2,000 km, LOFAR has the unique capability of achieving sub-arcsecond resolution at frequencies below 200 MHz, although this is technically and logistically challenging. Here we present a calibration strategy that builds on previous high-resolution work with LOFAR. We give an overview of the calibration strategy and discuss the special challenges inherent to enacting high-resolution imaging with LOFAR, and describe the pipeline, which is publicly available, in detail. We demonstrate the calibration strategy by using the pipeline on P205+55, a typical LOFAR Two-metre Sky Survey (LoTSS) pointing. We perform in-field delay calibration, solution referencing to other calibrators, self-calibration, and imaging of example directions of interest in the field. For this specific field and these ionospheric conditions, dispersive delay solutions can be transferred between calibrators up to ~1.5 degrees away, while phase solution transferral works well over 1 degree. We demonstrate a check of the astrometry and flux density scale. Imaging in 17 directions, the restoring beam is typically 0.3" x 0.2" although this varies slightly over the entire 5 square degree field of view. We achieve ~80 to 300 $μ$Jy/bm image rms noise, which is dependent on the distance from the phase centre; typical values are ~90 $μ$Jy/bm for the 8 hour observation with 48 MHz of bandwidth. Seventy percent of processed sources are detected, and from this we estimate that we should be able to image ~900 sources per LoTSS pointing. This equates to ~3 million sources in the northern sky, which LoTSS will entirely cover in the next several years. Future optimisation of the calibration strategy for efficient post-processing of LoTSS at high resolution (LoTSS-HR) makes this estimate a lower limit.