Researcher profile

C. Ferrari

C. Ferrari contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2026arXiv

Light Dark Matter Search with 7.8 Tonne-Year of Ionization-Only Data in XENONnT

We report on a blinded search for dark matter (DM) using ionization-only (S2-only) signals in XENONnT with a total exposure of $7.83\mathrm{tonne}\times\mathrm{year}$ over 579 days in three science runs. Dedicated background suppression techniques and the first complete S2-only background model in XENONnT provide sensitivity to nuclear recoils of [0.5, 5.0] $\mathrm{keV_\mathrm{nr}}$ and electronic recoils of [0.04, 0.7] $\mathrm{keV_\mathrm{ee}}$. No significant excess over the expected background is observed, and we set 90\% confidence level upper limits on spin-independent DM--nucleon and spin-dependent DM--neutron scattering for DM masses between 3 and 8 $\mathrm{GeV}/c^2$, as well as on DM--electron scattering, axion-like particles, and dark photons, improving on previous constraints. For spin-independent DM--nucleon scattering, we exclude cross sections above $6.0\times10^{-45} $cm$^2$ at a DM mass of 5 $\mathrm{GeV}/c^2$, pushing the XENONnT sensitivity closer to the region where coherent elastic neutrino-nucleus scattering ($\text{CE}ν\text{NS}$) becomes an irreducible background.

preprint2022arXiv

First light of BEaTriX, the new testing facility for the modular X-ray optics of the ATHENA mission

The Beam Expander Testing X-ray facility (BEaTriX) is a unique X-ray apparatus now operated at the Istituto Nazionale di Astrofisica (INAF), Osservatorio Astronomico di Brera (OAB), in Merate, Italy. It has been specifically designed to measure the point spread function (PSF) and the effective area (EA) of the X-ray mirror modules (MMs) of the Advanced Telescope for High-ENergy Astrophysics (ATHENA), based on silicon pore optics (SPO) technology, for verification before integration into the mirror assembly. To this end, BEaTriX generates a broad, uniform, monochromatic, and collimated X-ray beam at 4.51 keV. [...] In BEaTriX, a micro-focus X-ray source with a titanium anode is placed in the focus of a paraboloidal mirror, which generates a parallel beam. A crystal monochromator selects the 4.51 keV line, which is expanded to the final size by a crystal asymmetrically cut with respect to the crystalline planes. [...] After characterization, the BEaTriX beam has the nominal dimensions of 170 mm x 60 mm, with a vertical divergence of 1.65 arcsec and a horizontal divergence varying between 2.7 and 3.45 arcsec, depending on the monochromator setting: either high collimation or high intensity. The flux per area unit varies from 10 to 50 photons/s/cm2 from one configuration to the other. The BEaTriX beam performance was tested using an SPO MM, whose entrance pupil was fully illuminated by the expanded beam, and its focus was directly imaged onto the camera. The first light test returned a PSF and an EA in full agreement with expectations. As of today, the 4.51 keV beamline of BEaTriX is operational and can characterize modular X-ray optics, measuring their PSF and EA with a typical exposure of 30 minutes. [...] We expect BEaTriX to be a crucial facility for the functional test of modular X-ray optics, such as the SPO MMs for ATHENA.

preprint2022arXiv

GPU-based optical simulation of the DARWIN detector

Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

preprint2022arXiv

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.

preprint2021arXiv

The ABALONE Photosensor

The ABALONE is a new type of photosensor produced by PhotonLab, Inc. with cost effective mass production, robustness and high performance. This modern technology provides sensitivity to visible and UV light, exceptional radio-purity and excellent detection performance in terms of intrinsic gain, afterpulsing rate, timing resolution and single-photon sensitivity. For these reasons, the ABALONE can have many fields of application, including particle physics experiments, such as DARWIN, and medical imaging. This new hybrid photosensor, that works as light intensifier, is based on the acceleration in vacuum of photoelectrons generated in a traditional photosensor cathode and guided towards a window of scintillating material that can be read from the outside through a silicon photomultiplier. In this work we present the simulation of the ABALONE and the results from operation at room temperature. The goal of the characterization is the evaluation of the gain, the response in time and the single photoelectron spectrum as a function of the electric field and the photoelectron emission angle. Details of future tests will be also discussed.

preprint2020arXiv

Performance of the Muon $g-2$ calorimeter and readout systems measured with test beam data

A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS data acquisition environment. The entire system performance was evaluated using 2.5 - 5 GeV electrons at the End Station Test Beam at SLAC. This paper includes a description of the individual subsystems and the results of measurements of the energy response and resolution, energy-scale stability, timing resolution, and spatial uniformity. All measured performances meet or exceed the $g-2$ experimental requirements. Based on the success of the tests, the complete production of the required 24 calorimeter stations has been made and installation into the main experiment is complete. Furthermore, the calorimeter response measurements determined here informed the design of the reconstruction algorithms that are now employed in the running $g-2$ experiment.