Source author record

C. -F. Cheng

C. -F. Cheng appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
1topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Improved Ionization and Dissociation Energies of the Deuterium Molecule

The ionization energy of D$_2$ has been determined experimentally from measurements involving two-photon Doppler-free vacuum-ultraviolet pulsed laser excitation and near-infrared continuous-wave laser excitation to yield $E_\mathrm{I}(\mathrm{D}_2)=124\,745.393\,739(26)$ \wn. From this value, the dissociation energy of D$_2$ is deduced to be $D_0$(D$_2$) = 36\,748.362\,282(26) \wn, representing a 25-fold improvement over previous values, and found in good agreement (at $1.6σ$) with recent ab initio calculations of the 4-particle nonadiabatic relativistic energy and of quantum-electrodynamic corrections up to order $mα^6$. This result constitutes a test of quantum electrodynamics in the molecular domain, while a perspective is opened to determine nuclear charge radii from molecules.

preprint2015arXiv

Doppler broadening thermometry based on cavity ring-down spectroscopy

A Doppler broadening thermometry (DBT) instrument is built based on cavity ring-down spectroscopy (CRDS) for precise determination of the Boltzmann constant. Compared with conventional direct absorption methods, the high-sensitivity of CRDS allows to reach a satisfied precision at lower sample pressures, which also reduces the influence due to collisions. By recording the spectrum of C$_2$H$_2$ at 787 nm, we demonstrate a statistical uncertainty of 6 ppm (part per million) in the determined linewidth values by several hours' measurement at a sample pressure of 1.5 Pa. The influence on the spectroscopy-determined temperatures has been investigated, including the "hidden" weak lines overlapped with the selected transition for DBT measurements. The reproducibility has also been examined to be better than 10 ppm, and it indicates that the instrument is feasible for DBT measurement toward a precision at the ppm level.