Source author record

C. -F. Cheng

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
1topics
4close collaborators

Published work

2 publications

preprint2022arXiv

Improved Ionization and Dissociation Energies of the Deuterium Molecule

The ionization energy of D2_2 has been determined experimentally from measurements involving two-photon Doppler-free vacuum-ultraviolet pulsed laser excitation and near-infrared continuous-wave laser excitation to yield EI(D2)=124 745.393 739(26)E_\mathrm{I}(\mathrm{D}_2)=124\,745.393\,739(26) \wn. From this value, the dissociation energy of D2_2 is deduced to be D0D_0(D2_2) = 36\,748.362\,282(26) \wn, representing a 25-fold improvement over previous values, and found in good agreement (at 1.6σ1.6σ) with recent ab initio calculations of the 4-particle nonadiabatic relativistic energy and of quantum-electrodynamic corrections up to order mα6mα^6. This result constitutes a test of quantum electrodynamics in the molecular domain, while a perspective is opened to determine nuclear charge radii from molecules.

preprint2015arXiv

Doppler broadening thermometry based on cavity ring-down spectroscopy

A Doppler broadening thermometry (DBT) instrument is built based on cavity ring-down spectroscopy (CRDS) for precise determination of the Boltzmann constant. Compared with conventional direct absorption methods, the high-sensitivity of CRDS allows to reach a satisfied precision at lower sample pressures, which also reduces the influence due to collisions. By recording the spectrum of C2_2H2_2 at 787 nm, we demonstrate a statistical uncertainty of 6 ppm (part per million) in the determined linewidth values by several hours' measurement at a sample pressure of 1.5 Pa. The influence on the spectroscopy-determined temperatures has been investigated, including the "hidden" weak lines overlapped with the selected transition for DBT measurements. The reproducibility has also been examined to be better than 10 ppm, and it indicates that the instrument is feasible for DBT measurement toward a precision at the ppm level.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.