Researcher profile

C. Amsler

C. Amsler contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

A cryogenic tracking detector for antihydrogen detection in the AEgIS experiment

We present the commissioning of the Fast Annihilation Cryogenic Tracker detector (FACT), installed around the antihydrogen production trap inside the 1 T superconducting magnet of the AEgIS experiment. FACT is designed to detect pions originating from the annihilation of antiprotons. Its 794 scintillating fibers operate at 4 K and are read out by silicon photomultipliers (MPPCs) at near room temperature. FACT provides the antiproton/antihydrogen annihilation position information with a few ns timing resolution. We present the hardware and software developments which led to the successful operation of the detector for antihydrogen detection and the results of an antiproton-loss based efficiency assessment. The main background to the antihydrogen signal is that of the positrons impinging onto the positronium conversion target and creating a large amount of gamma rays which produce a sizeable signal in the MPPCs shortly before the antihydrogen signal is expected. We detail the characterization of this background signal and its impact on the antihydrogen detection efficiency.

preprint2022arXiv

Cyclotron cooling to cryogenic temperature in a Penning-Malmberg trap with a large solid angle acceptance

Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, resulting in significantly reduced plasma temperature.

preprint2022arXiv

Minimizing plasma temperature for antimatter mixing experiments

The ASACUSA collaboration produces a beam of antihydrogen atoms by mixing pure positron and antiproton plasmas in a strong magnetic field with a double cusp geometry. The positrons cool via cyclotron radiation inside the cryogenic trap. Low positron temperature is essential for increasing the fraction of antihydrogen atoms which reach the ground state prior to exiting the trap. Many experimental groups observe that such plasmas reach equilibrium at a temperature well above the temperature of the surrounding electrodes. This problem is typically attributed to electronic noise and plasma expansion, which heat the plasma. The present work reports anomalous heating far beyond what can be attributed to those two sources. The heating seems to be a result of the axially open trap geometry, which couples the plasma to the external (300 K) environment via microwave radiation.

preprint2022arXiv

Studies of the linearity and stability of Silicon Drift Detectors for kaonic atoms X-ray spectroscopy

The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in terms of linearity and stability. The paper presents preliminary results for the linearity determination and stability monitoring of the SDDs system during the measurement of kaonic deuterium carried out in the summer of 2022.

preprint2020arXiv

Coupled Channel Analysis of $\bar{p} p \rightarrow π^0 π^0 η$, $π^0 ηη$ and $K^+ K^- π^0$ at 900 $MeV/c$ and of $ππ$-Scattering Data

A partial wave analysis of antiproton-proton annihilation data in flight at 900 $MeV/c$ into $π^0 π^0 η$ , $π^0 ηη$ and $K^+ K^- π^0$ is presented. The data were taken at LEAR by the Crystal Barrel experiment in 1996. The three channels have been coupled together with $ππ$-scattering isospin I=0 S- and D-wave as well as I=1 P-wave data utilizing the K-matrix approach. Analyticity is treated using Chew-Mandelstam functions. In the fit all ingredients of the K-matrix, including resonance masses and widths, were treated as free parameters. In spite of the large number of parameters, the fit results are in the ballpark of the values published by the Particle Data Group. In the channel $π^0 π^0 η$ a significant contribution of the spin exotic $I^G=1^-$ $J^{PC}=1^{-+}$ $π_1$-wave with a coupling to $π^0 η$ is observed. Furthermore the contributions of $ϕ(1020) π^0$ and $K^*(892)^\pm K^\mp$ in the channel $K^+ K^- π^0$ have been studied in detail. The differential production cross section for the two reactions and the spin-density-matrix elements for the $ϕ(1020)$ and $K^*(892)^\pm$ have been extracted. No spin-alignment is observed for both vector mesons. The spin density matrix elements have been also determined for the spin exotic wave.

preprint2020arXiv

Spin Density Matrix of the $ω$ in the Reaction $\bar{p} p \, \rightarrow \, ωπ^0$

The spin density matrix of the $ω$ has been determined for the reaction $\bar{p} p \, \rightarrow \, ωπ^0$ with unpolarized in-flight data measured by the Crystal Barrel LEAR experiment at CERN. The two main decay modes of the $ω$ into $π^0 γ$ and $π^+ π^- π^0$ have been separately analyzed for various $\bar{p}$ momenta between 600 and 1940 MeV/c. The results obtained with the usual method by extracting the matrix elements via the $ω$ decay angular distributions and with the more sophisticated method via a full partial wave analysis are in good agreement. A strong spin alignment of the $ω$ is clearly visible in this energy regime and all individual spin density matrix elements exhibit an oscillatory dependence on the production angle. In addition, the largest contributing orbital angular momentum of the $\bar{p}p$ system has been identified for the different beam momenta. It increases from $L^{max}_{\bar{p}p}$ = 2 at 600 MeV/c to $L^{max}_{\bar{p}p}$ = 5 at 1940 MeV/c.