Source author record

Björn Kreher

Björn Kreher appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2023arXiv

Learning Perspective Deformation in X-Ray Transmission Imaging

In cone-beam X-ray transmission imaging, perspective deformation causes difficulty in direct, accurate geometric assessments of anatomical structures. In this work, the perspective deformation correction problem is formulated and addressed in a framework using two complementary (180°) views. The complementary view setting provides a practical way to identify perspectively deformed structures by assessing the deviation between the two views. It also provides bounding information and reduces uncertainty for learning perspective deformation. Two representative networks Pix2pixGAN and TransU-Net for correcting perspective deformation are investigated. Experiments on numerical bead phantom data demonstrate the advantage of complementary views over orthogonal views or a single view. They show that Pix2pixGAN as a fully convolutional network achieves better performance in polar space than Cartesian space, while TransU-Net as a transformer-based hybrid network achieves comparable performance in Cartesian space to polar space. Further study demonstrates that the trained model has certain tolerance to geometric inaccuracy within calibration accuracy. The efficacy of the proposed framework on synthetic projection images from patients' chest and head data as well as real cadaver CBCT projection data and its robustness in the presence of bulky metal implants and surgical screws indicate the promising aspects of future real applications.

preprint2022arXiv

Simulation-Driven Training of Vision Transformers Enabling Metal Segmentation in X-Ray Images

In several image acquisition and processing steps of X-ray radiography, knowledge of the existence of metal implants and their exact position is highly beneficial (e.g. dose regulation, image contrast adjustment). Another application which would benefit from an accurate metal segmentation is cone beam computed tomography (CBCT) which is based on 2D X-ray projections. Due to the high attenuation of metals, severe artifacts occur in the 3D X-ray acquisitions. The metal segmentation in CBCT projections usually serves as a prerequisite for metal artifact avoidance and reduction algorithms. Since the generation of high quality clinical training is a constant challenge, this study proposes to generate simulated X-ray images based on CT data sets combined with self-designed computer aided design (CAD) implants and make use of convolutional neural network (CNN) and vision transformer (ViT) for metal segmentation. Model test is performed on accurately labeled X-ray test datasets obtained from specimen scans. The CNN encoder-based network like U-Net has limited performance on cadaver test data with an average dice score below 0.30, while the metal segmentation transformer with dual decoder (MST-DD) shows high robustness and generalization on the segmentation task, with an average dice score of 0.90. Our study indicates that the CAD model-based data generation has high flexibility and could be a way to overcome the problem of shortage in clinical data sampling and labelling. Furthermore, the MST-DD approach generates a more reliable neural network in case of training on simulated data.