Published work

4 published item(s)

preprint2016arXiv

High-Frequency Modeling and Simulation of a Single-Phase Three-Winding Transformer Including Taps in Regulating Winding

Transformer terminal equivalents obtained via admittance measurements are suitable for simulating high-frequency transient interaction between the transformer and the network. This paper augments the terminal equivalent approach with a measurement-based voltage transfer function model which permits calculation of voltages at internal points in the regulating winding. The approach is demonstrated for a single-phase three-winding transformer in tap position Nom+ with inclusion of three internal points in the regulating winding that represent the mid-point and the two extreme ends. The terminal equivalent modeling makes use of additional common-mode measurements to avoid error magnifications to result from the ungrounded tertiary winding. The final model is used in a time domain simulation where ground-fault initiation results in a resonant voltage build-up in the winding. It is shown that that the peak value of the resonant overvoltage can be higher than during the lightning impulse test, with unfavorable network conditions. Additional measurements show that the selected tap position affects the terminal behavior of the transformer, changing the frequency and peak value of the lower resonance point in the voltage transfer between windings.

preprint2016arXiv

Variable Transmission Voltage for Loss Minimization in Long Offshore Wind Farm AC Export Cables

Connection of offshore wind farms to shore requires the use of submarine cables. In the case of long HVAC connections, the capacitive charging currents limit the transfer capability and lead to high losses. This paper shows that the losses can be substantially reduced by continuously adjusting the cable operating voltage according to the instantaneous wind farm power production.Calculations for a 320 MW windfarm connected to shore via a 200 km cable at 220 kV nominal voltage shows that an annual loss reduction of 9 percent is achievable by simply using a 15 percent tap changer voltage regulation on the two transformers. Allowing a larger voltage regulation range leads to further loss reduction (13 percent for 0.4-1.0 p.u. voltage range). If the windfarm has a low utilization factor, the loss reduction potential is demonstrated to be as high as 21 percent . The methodology can be applied without introducing new technology that needs to be developed or qualified.

preprint2014arXiv

Fast Computation of the Series Impedance of Power Cables with Inclusion of Skin and Proximity Effects

We present an efficient numerical technique for calculating the series impedance matrix of systems with round conductors. The method is based on a surface admittance operator in combination with the method of moments and it accurately predicts both skin and proximity effects. Application to a three-phase armored cable with wire screens demonstrates a speed-up by a factor of about 100 compared to a finite elements computation. The inclusion of proximity effect in combination with the high efficiency makes the new method very attractive for cable modeling within EMTP-type simulation tools. Currently, these tools can only take skin effect into account.

preprint2014arXiv

Proximity-Aware Calculation of Cable Series Impedance for Systems of Solid and Hollow Conductors

Wide-band cable models for the prediction of electromagnetic transients in power systems require the accurate calculation of the cable series impedance as function of frequency. A surface current approach was recently proposed for systems of round solid conductors, with inclusion of skin and proximity effects. In this paper we extend the approach to include tubular conductors, allowing to model realistic cables with tubular sheaths, armors and pipes. We also include the effect of a lossy ground. A noteworthy feature of the proposed technique is the accurate prediction of proximity effects, which can be of major importance in three-phase, pipe type, and closely-packed single-core cables. The new approach is highly efficient compared to finite elements. In the case of a cross-bonded cable system featuring three phase conductors and three screens, the proposed technique computes the required 120 frequency samples in only six seconds of CPU time.