Researcher profile

Bayan Karimi

Bayan Karimi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Ultimate accuracy of frequency to power conversion by single-electron injection

We analyze theoretically the properties of the recently introduced and experimentally demonstrated converter of frequency to power. The system is composed of a hybrid single-electron box with normal island and superconducting lead, and the detector of the energy flow using a thermometer on a normal metal bolometer. Here we consider its potential for metrology. The errors in power arise mainly from inaccuracy of injecting electrons at the precise energy equal to the energy gap of the superconductor. We calculate the main systematic error in form of the excess average energy of the injected electrons and its cumulants, and due to sub-gap leakage. We demonstrate by analytic and numerical calculations that the systematic error in detection can, in principle, be made much smaller than the injection errors, which also, with proper choice of system parameters, can be very small, < 1 %, at low enough temperature. Finally we propose a simplified configuration for metrological purposes.

preprint2021arXiv

Influence of device non-uniformities on the accuracy of Coulomb blockade thermometry

We investigate temperature errors of Coulomb blockade thermometer (CBT) arising from inevitable non-uniformities in tunnel junction arrays. The errors are proportional to the junction resistance variance in the universal operation regime and this result holds approximately also beyond this originally studied high temperature range. We present both analytical and numerical results, and discuss briefly their implications on achievable uniformity based on state-of-the-art fabrication of sensors.

preprint2020arXiv

Quantum trajectory analysis of single microwave photon detection by nanocalorimetry

We apply quantum trajectory techniques to analyze a realistic set-up of a superconducting qubit coupled to a heat bath formed by a resistor, a system that yields explicit expressions of the relevant transition rates to be used in the analysis. We discuss the main characteristics of the jump trajectories and relate them to the expected outcomes (&#34;clicks&#34;) of a fluorescence measurement using the resistor as a nanocalorimeter. As the main practical outcome we present a model that predicts the time-domain response of a realistic calorimeter subject to single microwave photons, incorporating the intrinsic noise due to the fundamental thermal fluctuations of the absorber and finite bandwidth of a thermometer.

preprint2019arXiv

Optimized proximity thermometer for ultra-sensitive detection

We present a set of experiments to optimize the performance of the noninvasive thermometer based on proximity superconductivity. Current through a standard tunnel junction between an aluminum superconductor and a copper electrode is controlled by the strength of the proximity induced to this normal metal, which in turn is determined by the position of a direct superconducting contact from the tunnel junction. Several devices with different distances were tested. We develop a theoretical model based on Usadel equations and dynamic Coulomb blockade which reproduces the measured results and yields a tool to calibrate the thermometer and to optimize it further in future experiments.