Researcher profile

Baptiste Pialot

Baptiste Pialot contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
1topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2023arXiv

Sensitivity enhancement using chirp transmission for an ultrasound arthroscopic probe

Meniscal tear in the knee joint is a highly common injury that can require an ablation. However, the success rate of meniscectomy is highly impacted by difficulties in estimating the thin vascularization of the meniscus, which determines the healing capacities of the patient. Indeed, the vascularization is estimated using arthroscopic cameras that lack of a high sensitivity to blood flow. Here, we propose an ultrasound method for estimating the density of vascularization in the meniscus during surgery. This approach uses an arthroscopic probe driven by ultrafast sequences. To enhance the sensitivity of the method, we propose to use a chirp-coded excitation combined to a mismatched compression filter robust to the attenuation. This chirp approach was compared to a standard ultrafast emission and a Hadamard-coded emission using a flow phantom. The mismatched filter was also compared to a matched filter. Results show that, for a velocity of a few mm/s, the mismatched filter gives a 4.4 to 10.4 dB increase of the signal-to-noise ratio compared to the Hadamard emission and a 3.1 to 6.6 dB increase compared to the matched filter. Such increases are obtained for a loss of axial resolution of 13% when comparing the point spread functions of the mismatched and matched filters. Hence, the mismatched filter allows increasing significantly the probe capacity to detect slow flows at the cost of a small loss in axial resolution. This preliminary study is the first step toward an ultrasensitive ultrasound arthroscopic probe able to assist the surgeon during meniscectomy.