Source author record

Baogen Sun

Baogen Sun appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2015arXiv

Beam size and position measurement based on logarithm processing algorithm in HLS II

A logarithm processing algorithm to measure beam transverse size and position is proposed and preliminary experimental results in Hefei Light Source II (HLS II) are given. The algorithm is based on only 4 successive channels of 16 anode channels of multianode photomultiplier tube (MAPMT) R5900U-00-L16 which has typical rise time of 0.6 ns and effective area of 0.8x16 mm for a single anode channel. In the paper, we firstly elaborate the simulation results of the algorithm with and without channel inconsistency. Then we calibrate the channel inconsistency and verify the algorithm using general current signal processor Libera Photon in low-speed scheme. Finally we get turn-by-turn beam size and position and calculate the vertical tune in high-speed scheme. The experimental results show that measured values fit well with simulation results after channel differences are calibrated and the fractional part of the tune in vertical direction is 0.3628 which is very close to the nominal value 0.3621.

preprint2015arXiv

Central frequency measurement of the HLS-II storage ring

Central frequency is a key parameter of storage rings. This paper presents the measurement of central frequency of the HLS-II storage ring using the sextupole modulation method. Firstly, the basis of central frequency measurement of the electron storage ring is briefly introduced. Then, the error sources and the optimized measurement method for the HLS-II storage ring are discussed. The workflow of the self-compiled Matlab script used in central frequency measurement is also described. In the end, the results achieved by using two methods to cross-check each other are shown. The measured value of the central frequency demonstrates that the real circumference of the HLS-II storage ring agrees well with the designed value.

preprint2013arXiv

A waveguide overloaded cavity kicker for the HLS II longitudinal feedback system

In the upgrade project of Hefei Light Source (HLS II), a new digital longitudinal bunch-by-bunch feedback system will be developed to suppress the coupled bunch instabilities in the storage ring effectively. We design a new waveguide overloaded cavity longitudinal feedback kicker as the feedback actuator. The beam pipe of the kicker is racetrack shape so as to avoid a transition part to the octagonal vacuum chamber. The central frequency and the bandwidth of the kicker have been simulated and optimized to achieve design goals by the HFSS code. The higher shunt impedance can be obtained by using a nose cone to reduce the feedback power requirement. Before the kicker cavity was installed in the storage ring, a variety of measurements were carried out to check its performance. All these results of simulation and measurement are presented.