Researcher profile

Bálint Hartmann

Bálint Hartmann contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
3topics
3close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Synchronization dynamics on the EU and US power grids

Dynamical simulation of the cascade failures on the EU and USA high-voltage power grids has been done via solving the second-order Kuramoto equation. We show that synchronization transition happens by increasing the global coupling parameter $K$ with metasatble states depending on the initial conditions so that hysteresis loops occur. We provide analytic results for the time dependence of frequency spread in the large $K$ approximation and by comparing it with numerics of $d=2,3$ lattices, we find agreement in the case of ordered initial conditions. However, different power-law (PL) tails occur, when the fluctuations are strong. After thermalizing the systems we allow a single line cut failure and follow the subsequent overloads with respect to threshold values $T$. The PDFs $p(N_f)$ of the cascade failures exhibit PL tails near the synchronization transition point $K_c$. Near $K_c$ the exponents of the PL-s for the US power grid vary with $T$ as $1.4 \le τ\le 2.1$, in agreement with the empirical blackout statistics, while on the EU power grid we find somewhat steeper PL-s characterized by $1.4 \le τ\le 2.4$. Below $K_c$ we find signatures of $T$-dependent PL-s, caused by frustrated synchronization, reminiscent of Griffiths effects. Here we also observe stability growth following the blackout cascades, similar to intentional islanding, but for $K > K_c$ this does not happen. For $T < T_c$, bumps appear in the PDFs with large mean values, known as &#34;dragon king&#34; blackout events. We also analyze the delaying/stabilizing effects of instantaneous feedback or increased dissipation and show how local synchronization behaves on geographic maps.

preprint2020arXiv

Power-law distributions of dynamic cascade failures in power-grid models

Power-law distributed cascade failures are well known in power-grid systems. Understanding this phenomena has been done by various DC threshold models, self-tuned at their critical point. Here we attempt to describe it using an AC threshold model, with a second-order Kuramoto type equation of motion of the power-flow. We have focused on the exploration of network heterogeneity effects, starting from homogeneous 2D lattices to the US power-grid, possessing identical nodes and links, to a realistic electric power-grid obtained from the Hungarian electrical database. The last one exhibits node dependent parameters, topologically marginally on the verge of robust networks. We show that too weak quenched heterogeneity, coming solely from the probabilistic self-frequencies of nodes (2D lattice) is not sufficient to find power-law distributed cascades. On the other hand too strong heterogeneity destroys the synchronization of the system. We found agreement with the empirically observed power-law failure size distributions on the US grid, as well as on the Hungarian networks near the synchronization transition point. We have also investigated the consequence of replacing the usual Gaussian self-frequencies to exponential distributed ones, describing renewable energy sources. We found a drop in the steady state synchronization averages, but the cascade size distribution both for the US and Hungarian systems remained insensitive and have kept the universal tails, characterized by the exponent $τ\simeq 1.8$. We have also investigated the effect of an instantaneous feedback mechanism in case of the Hungarian power-grid.