Researcher profile

B. T. Cleveland

B. T. Cleveland contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

A Search for Electron Neutrino Transitions to Sterile States in the BEST Experiment

The Baksan Experiment on Sterile Transitions (BEST) probes the gallium anomaly and its possible connections to oscillations between active and sterile neutrinos. Based on the Gallium-Germanium Neutrino Telescope (GGNT) technology of the SAGE experiment, BEST employs two zones of liquid Ga target to explore neutrino oscillations on the meter scale. Oscillations on this short scale could produce deficits in the $^{71}$Ge production rates within the two zones, as well as a possible rate difference between the zones. From July 5th to October 13th 2019, the two-zone target was exposed to a primarily monoenergetic, 3.4-MCi $^{51}$Cr neutrino source 10 times for a total of 20 independent $^{71}$Ge extractions from the two Ga targets. The $^{71}$Ge production rates from the neutrino source were measured from July 2019 to March 2020. At the end of these measurements, the counters were filled with $^{71}$Ge doped gas and calibrated during November 2020. In this paper, results from the BEST sterile neutrino oscillation experiment are presented in details. The ratio of the measured $^{71}$Ge production rates to the predicted rates for the inner and the outer target volumes are calculated from the known neutrino capture cross section. Comparable deficits in the measured ratios relative to predicted values are found for both zones, with the $4 σ$ deviations from unity consistent with the previously reported gallium anomaly. If interpreted in the context of neutrino oscillations, the deficits give best fit oscillation parameters of $Δm^2=3.3^{+\infty}_{-2.3}$ eV$^2$ and sin$^2 2θ=0.42^{+0.15}_{-0.17}$, consistent with $ν_e \rightarrow ν_s$ oscillations governed by a surprisingly large mixing angle.

preprint2022arXiv

Constraints on dark matter-nucleon effective couplings in the presence of kinematically distinct halo substructures using the DEAP-3600 detector

DEAP-3600 is a single-phase liquid argon detector aiming to directly detect Weakly Interacting Massive Particles (WIMPs), located at SNOLAB (Sudbury, Canada). After analyzing data taken during the first year of operation, a null result was used to place an upper bound on the WIMP-nucleon spin-independent, isoscalar cross section. This study reinterprets this result within a Non-Relativistic Effective Field Theory framework, and further examines how various possible substructures in the local dark matter halo may affect these constraints. Such substructures are hinted at by kinematic structures in the local stellar distribution observed by the Gaia satellite and other recent astronomical surveys. These include the Gaia Sausage (or Enceladus), as well as a number of distinct streams identified in recent studies. Limits are presented for the coupling strength of the effective contact interaction operators $\mathcal{O}_1$, $\mathcal{O}_3$, $\mathcal{O}_5$, $\mathcal{O}_8$, and $\mathcal{O}_{11}$, considering isoscalar, isovector, and xenonphobic scenarios, as well as the specific operators corresponding to millicharge, magnetic dipole, electric dipole, and anapole interactions. The effects of halo substructures on each of these operators are explored as well, showing that the $\mathcal{O}_5$ and $\mathcal{O}_8$ operators are particularly sensitive to the velocity distribution, even at dark matter masses above 100 GeV/$c^2$.

preprint2022arXiv

First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector

Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scatter signals. No candidate signal events were observed, leading to the first direct detection constraints on Planck-scale mass dark matter. Leading limits constrain dark matter masses between $8.3\times10^{6}$ and $1.2\times10^{19} \text{GeV}/c^2$, and cross sections for scattering on $^{40}$Ar between $1.0\times10^{-23}$ and $2.4\times10^{-18} \text{cm}^2$. These are used to constrain two composite dark matter models.

preprint2022arXiv

Results from the Baksan Experiment on Sterile Transitions (BEST)

The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos, $ν_{e}$, observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the \textit{gallium anomaly}, which could be interpreted as evidence for oscillations between $ν_e$ and sterile neutrino ($ν_s$) states. A 3.414-MCi \nuc{51}{Cr} $ν_e$ source was placed at the center of two nested Ga volumes and measurements were made of the production of \nuc{71}{Ge} through the charged current reaction, \nuc{71}{Ga}($ν_e$,e$^-$)\nuc{71}{Ge}, at two average distances. The measured production rates for the inner and the outer targets respectively are ($54.9^{+2.5}_{-2.4}(\mbox{stat})\pm1.4 (\mbox{syst})$) and ($55.6^{+2.7}_{-2.6}(\mbox{stat})\pm1.4 (\mbox{syst})$) atoms of \nuc{71}{Ge}/d. The ratio ($R$) of the measured rate of \nuc{71}{Ge} production at each distance to the expected rate from the known cross section and experimental efficiencies are $R_{in}=0.79\pm0.05$ and $R_{out}= 0.77\pm0.05$. The ratio of the outer to the inner result is 0.97$\pm$0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20-24\% lower than expected, thus reaffirming the anomaly. These results are consistent with $ν_e \rightarrow ν_s$ oscillations with a relatively large $Δm^2$ ($>$0.5 eV$^2$) and mixing sin$^2 2θ$ ($\approx$0.4).

preprint2020arXiv

The liquid-argon scintillation pulseshape in DEAP-3600

DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic background events. The excellent PSD performance of LAr makes it a viable target for dark matter searches, and the LAr scintillation pulseshape discussed here is the basis of PSD. The observed pulseshape is a combination of LAr scintillation physics with detector effects. We present a model for the pulseshape of electromagnetic background events in the energy region of interest for dark matter searches. The model is composed of a) LAr scintillation physics, including the so-called intermediate component, b) the time response of the TPB wavelength shifter, including delayed TPB emission at $\mathcal O$(ms) time-scales, and c) PMT response. TPB is the wavelength shifter of choice in most LAr detectors. We find that approximately 10\% of the intensity of the wavelength-shifted light is in a long-lived state of TPB. This causes light from an event to spill into subsequent events to an extent not usually accounted for in the design and data analysis of LAr-based detectors.